2018
DOI: 10.1016/j.jvc.2018.01.001
|View full text |Cite
|
Sign up to set email alerts
|

High-pressure balloon valvuloplasty for severe pulmonary valve stenosis: a prospective observational pilot study in 25 dogs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
10
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 17 publications
1
10
0
Order By: Relevance
“…In both alpacas, the maximum balloon diameter was selected based on current recommendations to achieve a balloon-to-annulus ratio (BA) of approximately 1.3 to 1.5, although a more permissive ratio of 1.2 to 1.5 has also been suggested. 5,8,9,14,[16][17][18] The effective BA for cases 1 and 2 were 1.55 and 1.33, respectively. A double-balloon procedure was employed for the former, as achieving the target BA would have required use of a single balloon with a diameter exceeding 20 mm.…”
Section: Discussionmentioning
confidence: 97%
See 3 more Smart Citations
“…In both alpacas, the maximum balloon diameter was selected based on current recommendations to achieve a balloon-to-annulus ratio (BA) of approximately 1.3 to 1.5, although a more permissive ratio of 1.2 to 1.5 has also been suggested. 5,8,9,14,[16][17][18] The effective BA for cases 1 and 2 were 1.55 and 1.33, respectively. A double-balloon procedure was employed for the former, as achieving the target BA would have required use of a single balloon with a diameter exceeding 20 mm.…”
Section: Discussionmentioning
confidence: 97%
“…Thus, a double‐balloon technique was selected as the most efficient means of applying sufficient radial force to the PV while limiting hemodynamic disturbances. 16 , 18 When using this approach, the effective balloon diameter is calculated with the equation 0.82(Diameter 1 + Diameter 2), where diameters 1 and 2 refer to each balloon. 17 , 18 The 16 mm balloons that were initially selected for case 2 yielded a BA of 1.2, and resolution of the PV waist was achieved only after converting to a balloon with a BA of 1.33.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The technique used in the present case, balloon valvuloplasty, is the technique of choice for pulmonary valve stenosis, performed in conjunction with cardiac catheterization, dilating the stenosed area with balloon insufflation (Treseder & Jung, 2017;Belanger et al, 2018). This technique reduces the pulmonary artery pressure gradient from 40 to 60%, improving the clinical signs and in some situations the echocardiographic parameters, as observed in the report, where the thickness of the interventricular septum and the pressure gradient in the pulmonary artery decreased progressively over the years after balloon valvuloplasty (Bussadori et al, 2001;Locatelli et al, 2011;Strickland & Oyama, 2016).…”
Section: Discussionmentioning
confidence: 99%