2012
DOI: 10.1016/j.jct.2012.05.008
|View full text |Cite
|
Sign up to set email alerts
|

High-pressure density measurements for choline chloride: Urea deep eutectic solvent and its aqueous mixtures at T= (298.15 to 323.15) K and up to 50 MPa

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

10
91
2
1

Year Published

2013
2013
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 135 publications
(104 citation statements)
references
References 50 publications
10
91
2
1
Order By: Relevance
“…The measurements were performed at 10°intervals in the temperature range of 293.15 K to 363.15 K. Table 2 presents comparison of densities of pure reline and their aqueous mixtures measured with our instrumentation with those available in literature. 35 Our values are in good agreement with those reported in the literature. The dynamic viscosities (η) were measured with a Peltier-based (resolution of 0.01 K and accuracy < 0.05 K) automated Anton Paar microviscometer (model AMVn) having calibrated glass capillaries of different diameters (1.6, 1.8, 3.0, and 4.0 mm).…”
Section: ■ Experimental Sectionsupporting
confidence: 92%
See 2 more Smart Citations
“…The measurements were performed at 10°intervals in the temperature range of 293.15 K to 363.15 K. Table 2 presents comparison of densities of pure reline and their aqueous mixtures measured with our instrumentation with those available in literature. 35 Our values are in good agreement with those reported in the literature. The dynamic viscosities (η) were measured with a Peltier-based (resolution of 0.01 K and accuracy < 0.05 K) automated Anton Paar microviscometer (model AMVn) having calibrated glass capillaries of different diameters (1.6, 1.8, 3.0, and 4.0 mm).…”
Section: ■ Experimental Sectionsupporting
confidence: 92%
“…Densities of aqueous mixtures of reline have been measured by other researchers. In a recent study, Li et al 35 reported the high-pressure densities of reline and their aqueous mixtures under pressures up to 50 MPa and temperatures of 298.15 K to 323.15 K. However, the temperature range of this report is significantly narrower. Various pharmaceutical and biotechnological industries and chemical engineering processes require knowledge of viscosity and its temperature dependence as an essential piece of information.…”
Section: ■ Introductionmentioning
confidence: 65%
See 1 more Smart Citation
“…Figure 1, shows a comparison between the measured density data of this work with those reported in the literature for the DES10-2 (ChCl:urea, 1:2). The density data generated by this work deviates by an average of 1.41% from those reported by Yadav and Pandey [16] and Liron and Li [29]. This may be due to the method of preparing the DES.…”
Section: Resultscontrasting
confidence: 73%
“…The overall estimated uncertainty of the measurements was ±0.1% while the accuracy of the proposed correlation was ±0.003%. The detailed experimental procedure for the density measurements, including the apparatus and the calibration method used, are discussed in our previous work [33]. The modified Tait-type equation is expressed as …”
Section: Calculation Of Buoyancy Effectsmentioning
confidence: 99%