2011
DOI: 10.1029/2011jd016032
|View full text |Cite
|
Sign up to set email alerts
|

High-resolution solar spectral irradiance from extreme ultraviolet to far infrared

Abstract: [1] This paper presents new extremely high-resolution solar spectral irradiance (SSI) calculations covering wavelengths from 0.12 nm to 100 micron obtained by the Solar Irradiance Physical Modeling (SRPM) system. Daily solar irradiance spectra were constructed for most of Solar Cycle 23 based on a set of physical models of the solar features and non-LTE calculations of their emitted spectra as function of viewing angle, and solar images specifying the distribution of features on the solar disk. Various observa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

11
266
2
2

Year Published

2011
2011
2015
2015

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 189 publications
(281 citation statements)
references
References 53 publications
(100 reference statements)
11
266
2
2
Order By: Relevance
“…Figure 1 shows a comparison between several line profiles along the spectra with increasing wavelength. With solid lines we indicate our calculation, with dashed lines the spectra calculated by Fontenla et al (2011) present only in the visible lines, and with doted lines the observations. The differences between the two synthetic profiles are in the NLTE calculations.…”
Section: The New Ni I Atomic Model and Spectral Synthesis Calculationsmentioning
confidence: 99%
See 4 more Smart Citations
“…Figure 1 shows a comparison between several line profiles along the spectra with increasing wavelength. With solid lines we indicate our calculation, with dashed lines the spectra calculated by Fontenla et al (2011) present only in the visible lines, and with doted lines the observations. The differences between the two synthetic profiles are in the NLTE calculations.…”
Section: The New Ni I Atomic Model and Spectral Synthesis Calculationsmentioning
confidence: 99%
“…In our case the populations were calculated in full NLTE with 61 levels. The spectra calculated by Fontenla et al (2011) considered NLTE calculation only for 10 levels, and then they approximated the departure coefficients of the rest of the levels with the value obtained for the last level calculated in NLTE.…”
Section: The New Ni I Atomic Model and Spectral Synthesis Calculationsmentioning
confidence: 99%
See 3 more Smart Citations