2004
DOI: 10.1016/j.jms.2004.03.009
|View full text |Cite
|
Sign up to set email alerts
|

High sensitivity cw-cavity ringdown and Fourier transform absorption spectroscopies of 13CO2

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
89
1

Year Published

2004
2004
2024
2024

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 72 publications
(96 citation statements)
references
References 35 publications
6
89
1
Order By: Relevance
“…With respect to the fibered DFB laser set-up used here, it was presented in detail in [19] and applied in the same spectral region to the spectroscopy of carbon dioxide [20]. The reader is referred to these references for more details.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…With respect to the fibered DFB laser set-up used here, it was presented in detail in [19] and applied in the same spectral region to the spectroscopy of carbon dioxide [20]. The reader is referred to these references for more details.…”
Section: Methodsmentioning
confidence: 99%
“…After linearization of the wavenumber scale using fringes of an etalon (see [20] for more details), the spectrum was absolutely calibrated using accurate values of water line positions given in [11] and included in the HITRAN database [22]. We estimate the accuracy of the wavenumber calibration to be better than 0.002 cm À1 as confirmed by (i) the comparison of the line positions measured in the overlapping spectral region corresponding to two successive DFB lasers, (ii) the comparison of the line positions measured by Fourier transform spectroscopy [11,13], and also those obtained recently in the 4200-6600 cm À1 spectral region by the Bruxelles-Reims group with the same 50 m multipass cell associated to a mobile Bruker 120 M spectrometer which was previously applied in the near infrared and visible regions [23,24], and (iii) the rotational analysis (see below) which leads to uncertainty values of the energy levels, generally better than 0.001 cm À1 even if transitions reaching a given upper state are generally spread over several spectral sections which were calibrated independently.…”
Section: Wavenumber Calibrationmentioning
confidence: 99%
“…We compared the CO 2 (g) vibrational frequencies and C@O bond lengths using each method/basis set combination with measured frequencies, corrected for anharmonicity (Table A4) (Tashkun et al, 1998;Ding et al, 2004). The QCISD/6-311++G(2d,2p) model has the smallest rootmean squared misfit (RMS 11 ) (13.8 cm…”
Section: A22 Comparison Of Measured and Model Co 2 (G) Vibrationalmentioning
confidence: 99%
“…It allows a continuous coverage of the 6130-6750 cm À1 spectral region, with a typical sensitivity of 5 · 10 À10 cm À1 . The same setup has recently been applied to the spectroscopy of water vapor [9] and of the 13 CO 2 isotopologue [10].…”
Section: Introductionmentioning
confidence: 99%