High sensitivity radiochromic film dosimetry using an optical common‐mode rejection and a reflective‐mode flatbed color scanner

Abstract: A novel method that can greatly improve the dosimetric sensitivity limit of a radiochromic film (RCF) through use of a set of color components, e.g., red and green, outputs from a RGB color scanner has been developed. RCFs are known to have microscopic and macroscopic nonuniformities, which come from the thickness variations in the film's active radiochromic layer and coating. These variations in the response make the optical signal-to-noise ratio lower, resulting in lower film sensitivity. To mitigate the eff… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
16
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(16 citation statements)
references
References 27 publications
0
16
0
Order By: Relevance
“…Ohuchi and Papaconstadopoulos et al reported that reflectance can be processed like transmittance because a radiochromic film's active layer is transparent. 29,30 The CLOD also used the active layer of the film. Therefore, the response to irradiation was quantified in terms of optical density (OD) values.…”
Section: C Clod Calibration and Scanning Protocolmentioning
confidence: 99%
See 1 more Smart Citation
“…Ohuchi and Papaconstadopoulos et al reported that reflectance can be processed like transmittance because a radiochromic film's active layer is transparent. 29,30 The CLOD also used the active layer of the film. Therefore, the response to irradiation was quantified in terms of optical density (OD) values.…”
Section: C Clod Calibration and Scanning Protocolmentioning
confidence: 99%
“…where Rf denotes the reflectance of the irradiated CLOD, Rf 0 denotes the reflectance of the nonirradiated CLOD, and Rf bg denotes the background reflectance without the CLOD. 29,31 In addition to these scanning protocols, the dependence of scanning orientation was investigated by rotating the CLOD above the scanner bed in intervals of 30°. The netOD value of the CLOD irradiated with 100 cGy was normalized to a 0°r eading.…”
Section: C Clod Calibration and Scanning Protocolmentioning
confidence: 99%
“…This definition was also employed by Butson et al 2 and a similar one was used by Ohuchi 15 for reflected optical density. The (UVA + UVB) irradiance (power per unit area, W m −2 ) and exposure (irradiance integrated over time, J cm −2 or J m −2 ) were measured.…”
mentioning
confidence: 99%
“…This is borrowed from the tradition of radiographic film dosimetry, in which the degree of film darkening is quantified in terms of optical density and converted into applied dose. Even though dose assessment is traditionally carried out by transmission measurement, some authors 22,23 proposed the reflection mode for the reading of radiochromic film. A transparent film can be read in reflection mode by placing it upon a diffuse white surface, which is available in most flatbed scanners.…”
Section: Introductionmentioning
confidence: 99%