High-speed gas chromatography in doping control: Fast-GC and fast-GC/MS determination of β-adrenoceptor ligands and diuretics

Abstract: In official doping controls, about 300 drugs and metabolites have to be screened for each sample. Moreover, the number of determinations to be routinely processed increases continuously as the number of both samples and potential illicit drugs keeps growing. As a consequence, increasingly specific, sensitive, and, above all, fast methods for doping controls are needed. The present study presents an efficient fast-GC/MS approach to the routine screening of two different classes of doping agents, namely beta-adr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
32
0

Year Published

2008
2008
2015
2015

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 55 publications
(32 citation statements)
references
References 12 publications
0
32
0
Order By: Relevance
“…(52) A similar two-step derivatization approach was used for β-adrenoceptor ligands and methyl iodide in potassium carbonate and acetone methylated the diuretics before GC/MS of these mixtures in about 5 min using narrow bore capillary columns. (53) To enhance SPME using a polystyrene-divinylbenzene fiber, phenazone drugs were first acetylated on the nitrogen atom using acetic anhydride but then silylated with MTBSTFA, which removes the acetyl group to enhance GC/MS detection. (54) Pentafluorophenyldimethylsilyl (flophemesyl) derivatives are often generated from steroids by reaction with flophemesylamine at room temperature for 15 min.…”
Section: Silylationmentioning
confidence: 99%
“…(52) A similar two-step derivatization approach was used for β-adrenoceptor ligands and methyl iodide in potassium carbonate and acetone methylated the diuretics before GC/MS of these mixtures in about 5 min using narrow bore capillary columns. (53) To enhance SPME using a polystyrene-divinylbenzene fiber, phenazone drugs were first acetylated on the nitrogen atom using acetic anhydride but then silylated with MTBSTFA, which removes the acetyl group to enhance GC/MS detection. (54) Pentafluorophenyldimethylsilyl (flophemesyl) derivatives are often generated from steroids by reaction with flophemesylamine at room temperature for 15 min.…”
Section: Silylationmentioning
confidence: 99%
“…The recovery of diuretics and impeding effect of urine matrix and other diuretics were not studied in this work as well as in [10]. Besides, both methods were not validated.…”
Section: Introductionmentioning
confidence: 97%
“…Despite the great number of methods proposed, gas or liquid chromatography with mass spectrometric detection do not always provide the necessary selectivity towards the urine components [10,12]. In case of liquid chromatography, the use of tandem mass-spectrometry allowed to pass over these problems and to ensure the satisfactory result [13][14][15].…”
Section: Introductionmentioning
confidence: 99%
“…The convenient application of such a technique in antidoping analysis, using short and narrow columns (5-10 m, i.d. 0.05-0.1 mm), fast temperature ramping and high carrier gas fl ow rate was recently demonstrated (Morra et al, 2006;Brunelli et al, 2006;Mazzarino et al, 2007).…”
Section: Introductionmentioning
confidence: 98%