2017
DOI: 10.1007/s11085-017-9713-9
|View full text |Cite
|
Sign up to set email alerts
|

High-Temperature Oxidation of Zircaloy-4 in Air Studied with Labeled Oxygen and Raman Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…This experimental assessment was further confirmed using ab initio calculations . In addition, measurements of the zone‐centre Raman wavenumbers for zirconia can be used as a versatile method to determine the isotopic concentration ratio with a fair accuracy . This might be directly applied in two‐stage oxidation experiments using isotopes as diffusion tracers, which are known in the corrosion community to give valuable inputs on diffusion processes .…”
Section: Introductionmentioning
confidence: 69%
See 1 more Smart Citation
“…This experimental assessment was further confirmed using ab initio calculations . In addition, measurements of the zone‐centre Raman wavenumbers for zirconia can be used as a versatile method to determine the isotopic concentration ratio with a fair accuracy . This might be directly applied in two‐stage oxidation experiments using isotopes as diffusion tracers, which are known in the corrosion community to give valuable inputs on diffusion processes .…”
Section: Introductionmentioning
confidence: 69%
“…This might be directly applied in two‐stage oxidation experiments using isotopes as diffusion tracers, which are known in the corrosion community to give valuable inputs on diffusion processes . For such a purpose, it has been demonstrated that 18 O concentration profiles or maps compare well with those that were extracted from secondary ion mass spectroscopy analysis . Finally, isotopic substitution can also be used to ascertain whether or not a given spectral structure is of vibrational origin or due to another type of excitation, for example, of electronic origin.…”
Section: Introductionmentioning
confidence: 99%
“…This is why we systematically used high 18 O content, for which the expected line shifts are by far higher than 1.5 cm -1 . In such cases, it has been shown that Raman and SIMS images compare well [19,23], and that stress effects can be neglected.…”
Section: O Concentration Determination Using Raman Spectroscopymentioning
confidence: 99%
“…Nevertheless, in the high 18 O 2154 concentration range, it has been shown that Raman and SIMS concentration images compared well, spatially as well as quantitatively. [80] Again, it is necessary to keep in mind that 18 O concentration estimates are averaged values within the probing spot (about 2 μm 3 ). Indeed, in the oxide layers, the grain size was found to lie between a few tens and a few hundred micrometers from SEM/FEG images.…”
Section: Consequences Of Oxygen Isotopic Substitution On the M-zro 2 ...mentioning
confidence: 99%
“…Nevertheless, in the high 18 O concentration range, it has been shown that Raman and SIMS concentration images compared well, spatially as well as quantitatively. [ 80 ]…”
Section: Using Labeled Oxygen During the Oxidation Testsmentioning
confidence: 99%