2006
DOI: 10.1002/rcm.2529
|View full text |Cite
|
Sign up to set email alerts
|

High‐throughput quantification of perindopril in human plasma by liquid chromatography/tandem mass spectrometry: application to a bioequivalence study

Abstract: A simple, sensitive and rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry method was developed and validated for the quantification of perindopril in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective [M+H](+) ions, m/z 369/172 for perindopril and m/z 417/234 for the internal standard. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
12
0

Year Published

2006
2006
2015
2015

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 26 publications
(12 citation statements)
references
References 16 publications
0
12
0
Order By: Relevance
“…In recent years, a number of laboratories have reported high-throughput bioanalytical procedures using LC-MS/ MS (Jemal, 2000;Nirogi et al, 2006;Ramakrishna et al, 2006). Our method is simple, sensitive, rapid and specific, which makes it an attractive procedure in highthroughput bioanalysis.…”
Section: Rimonabantmentioning
confidence: 99%
“…In recent years, a number of laboratories have reported high-throughput bioanalytical procedures using LC-MS/ MS (Jemal, 2000;Nirogi et al, 2006;Ramakrishna et al, 2006). Our method is simple, sensitive, rapid and specific, which makes it an attractive procedure in highthroughput bioanalysis.…”
Section: Rimonabantmentioning
confidence: 99%
“…Literature reported only few analytical methods for the determination of PDE in its bulk, dosage forms and human plasma, such as high performance liquid chromatography (Raju and Rao 2011;Zaazaa et al 2013;Riyaz et al 2012;Chaudhary et al 2010;Jogia et al 2010;Joseph et al 2011;Prajapati et al 2011a), HPLC-MS (Jaina et al 2006 andNirogi et al 2006), high performance thin layer chromatography (Dewani et al 2011), and spectrophotometry (Neelam et al 2012;Rahman et al 2012;Prajapati et al 2011b). However, the chromatographic methods were found to have certain drawbacks, such as the expensive instrumentation and high analysis cost.…”
Section: Introductionmentioning
confidence: 99%
“…Literature reported only few analytical methods for the determination of PDE in its bulk, dosage forms and human plasma, such as high performance liquid chromatography [2][3][4][5][6][7][8][9], HPLC-MS [10,11], high performance thin layer chromatography [12], and spectrophotometry [13][14][15][16].…”
Section: Introductionmentioning
confidence: 99%