2019
DOI: 10.1016/j.ijmultiphaseflow.2019.04.015
|View full text |Cite
|
Sign up to set email alerts
|

High-velocity air-water flows downstream of sluice gates including selection of optimum phase-detection probe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
23
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 32 publications
(26 citation statements)
references
References 53 publications
3
23
0
Order By: Relevance
“…Close to the channel bed and close to the free-surface y/Y 90 > 1.2, F tended to zero. In general, F increased with increasing flow rate, which is in agreement with previous studies of high-velocity air-water flows (e.g., Chanson & Toombes, 2002;Felder et al, 2019;Zhang & Chanson, 2017).…”
Section: Water Resources Researchsupporting
confidence: 92%
See 1 more Smart Citation
“…Close to the channel bed and close to the free-surface y/Y 90 > 1.2, F tended to zero. In general, F increased with increasing flow rate, which is in agreement with previous studies of high-velocity air-water flows (e.g., Chanson & Toombes, 2002;Felder et al, 2019;Zhang & Chanson, 2017).…”
Section: Water Resources Researchsupporting
confidence: 92%
“…Both electrodes were insulated by epoxide, resulting in a sudden drop in resistivity if the needle tip was in air, corresponding to a raw voltage of about 0.5 V and to a voltage of about 4.3 V when the probe tip was in water. The WRL double-tip conductivity probes have been previously successfully benchmarked against other phase-detection probes in high-velocity air-water flows (Felder et al, 2019;Felder & Pfister, 2017), and further details on the working principles can be found in Cartellier (1990), Chanson (2002a), andPfister (2017). The conductivity probes were carefully placed in flow direction perpendicularly to the chute to optimize the piercing of the air-water interfaces with the needle tips.…”
Section: Water Resources Researchmentioning
confidence: 99%
“…Cummings and Chanson, 1997) and fiber optical probes (e.g. Boes, 2000), as shown in Felder and Pfister (2017);Felder et al (2019). The measurement uncertainty of the conductivity probes in this manuscript is therefore expected to be similar to the data presented in table 1.…”
Section: A Glimpse On Measurement Accuracysupporting
confidence: 66%
“…A convergence analysis of the stepped spillway data showed that sampling durations T > 45 s could further improve the measurement accuracy (Appendix A). The raw voltage signals were recorded with the same LabVIEW-based data acquisition system using a high-speed acquisition unit (National Instruments USB-6366) and further details on the overall probe designs can be found in Felder and Pfister (2017) and Felder et al (2019). Table 3: Experimental flow condition and dual-tip phase-detection probe specifications for the re-analysed datasets; CP: phase-detection conductivity probe; FO: phase-detection fiber optical probe; Reynolds number Re = q/ν, with ν the kinematic viscosity of water and q the specific discharge; f : sampling rate, T : sampling duration; ∆ x: streamwise tip separation distance.…”
Section: General Remarksmentioning
confidence: 99%
See 1 more Smart Citation