2015
DOI: 10.1016/j.electacta.2015.06.061
|View full text |Cite
|
Sign up to set email alerts
|

Highly Sensitive Detection using Dual Working Electrode and Concentration Process in Electrochemical Metalloimmunoassay

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2016
2016
2025
2025

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 28 publications
0
3
0
Order By: Relevance
“…The typical size range of AgNS utilized in the past studies is between B5-100 nm. 19,20,24,26,27,30,33,35,42,80,115 For instance, Szymanski et al developed an immunosensor for detecting myoglobin, a cardiac heart marker, using AgNS (40 nm) as an electroactive label. 80 The AgNS were deposited onto a WE with help of an aggregating agent, NH 4 SCN, and a final anodic stripping voltammetry step was performed to detect the Ag oxidation current.…”
Section: Effect Of Agnp Shape and Size On The Ge Reactionmentioning
confidence: 99%
See 1 more Smart Citation
“…The typical size range of AgNS utilized in the past studies is between B5-100 nm. 19,20,24,26,27,30,33,35,42,80,115 For instance, Szymanski et al developed an immunosensor for detecting myoglobin, a cardiac heart marker, using AgNS (40 nm) as an electroactive label. 80 The AgNS were deposited onto a WE with help of an aggregating agent, NH 4 SCN, and a final anodic stripping voltammetry step was performed to detect the Ag oxidation current.…”
Section: Effect Of Agnp Shape and Size On The Ge Reactionmentioning
confidence: 99%
“…The oxidation current generated is directly correlated with the analyte concentration in the sample. Such AgNP-labeled sandwich-type immunoassays have been exploited to detect HBs 19 and the heart failure biomarker, N-terminal prohormone brain natriuretic peptide (NT-proBNP). 20 Also, some groups have employed more complex nanomaterials with AgNPs to improve the immunoassay sensitivity.…”
Section: Immunosensors Based On Direct Oxidation Of Agnp-labelsmentioning
confidence: 99%
“…It has been successfully employed in biosensing devices using SPEs [62,63]. An interesting approach was reported using a dual screen-printed working electrode device [64]. Working electrodes with different size were employed, and the biological reaction was carried out using both electrodes as heterogeneous surfaces.…”
Section: Strategies For Electrochemical Detection Of Nanoparticlesmentioning
confidence: 99%