2016
DOI: 10.1016/j.jlumin.2016.07.062
|View full text |Cite
|
Sign up to set email alerts
|

Hollow fluorescent carbon nanoparticles catalyzed chemiluminescence and its application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 38 publications
0
10
0
Order By: Relevance
“…In order to understand the possible mechanism, the CL spectra were obtained using the spectrofluorimeter with the light source taken off. From Figure , curve B, it is seen that no CL emission was present in the luminol solution, and the maximum wavelength of the GO–luminol and the GO–luminol–PUE systems was at 425 nm, which was similar to that of the luminol–H 2 O 2 CL system . Therefore, the luminophor in GO–luminol and GO–luminol–PUE systems was also the excited state of the 3‐aminophthalate anion (3‐APA*), an oxidation product of luminol.…”
Section: Resultsmentioning
confidence: 86%
“…In order to understand the possible mechanism, the CL spectra were obtained using the spectrofluorimeter with the light source taken off. From Figure , curve B, it is seen that no CL emission was present in the luminol solution, and the maximum wavelength of the GO–luminol and the GO–luminol–PUE systems was at 425 nm, which was similar to that of the luminol–H 2 O 2 CL system . Therefore, the luminophor in GO–luminol and GO–luminol–PUE systems was also the excited state of the 3‐aminophthalate anion (3‐APA*), an oxidation product of luminol.…”
Section: Resultsmentioning
confidence: 86%
“…In other words, the addition of CTAB–CDs did not lead to the generation of a new emitter, and they only acted as the catalysts to accelerate the electron‐transfer and the breakdown of H 2 O 2 to 1 O 2 intermediate, as shown in Figure . The 1 O 2 ‐induced CL enhancement has been further confirmed by Han and coworkers . They reported that the hollow fluorescent carbon nanoparticles (HFCNs) and solid fluorescent carbon nanoparticles (SFCNs) could both enhance the CL of the luminol–H 2 O 2 system, and the enhanced capability of HFCNs was superior to SFCNs.…”
Section: Cds‐assisted CL Systemsmentioning
confidence: 72%
“…3(A). The characteristic absorption peak at 3427 cm −1 can be assigned to O-H stretching vibrations 10 . Moreover, the peaks at 2924 cm -1 , 1403 cm -1 , and 653 cm -1 can be associated to stretching vibrations of C-H, C=C, and C=C-H out of plane bending, respectively 37 .…”
Section: Resultsmentioning
confidence: 99%
“…Moreover, the peaks at 2924 cm -1 , 1403 cm -1 , and 653 cm -1 can be associated to stretching vibrations of C-H, C=C, and C=C-H out of plane bending, respectively 37 . The peak at 1700 cm -1 indicates the presence of symmetric/asymmetric stretching vibrations of C=O 10 . Also, the bands at 1208-1370 cm…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation