2015
DOI: 10.1016/j.ergon.2015.06.003
|View full text |Cite
|
Sign up to set email alerts
|

How reliable are pressure measurements with Tekscan sensors on the body surface of human subjects wearing load carriage systems?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
37
0
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 34 publications
(38 citation statements)
references
References 22 publications
0
37
0
1
Order By: Relevance
“…To try solving this we applied a technique we called Period Averaging which helps to get more reliable results, but this has some limitations; for example, it can be applied only on signals which are known to have some form of periodicity. From literature analysis we found that when flexible sensors are used to measure skin interface pressure, results can be affected by inaccuracies due to the nonideality of the tissues that compose the human body [6,11]. In fact body softness variation due to bones prominence, sensor bending, and shear forces are effects always present in this kind of measurement that affects sensor's response.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…To try solving this we applied a technique we called Period Averaging which helps to get more reliable results, but this has some limitations; for example, it can be applied only on signals which are known to have some form of periodicity. From literature analysis we found that when flexible sensors are used to measure skin interface pressure, results can be affected by inaccuracies due to the nonideality of the tissues that compose the human body [6,11]. In fact body softness variation due to bones prominence, sensor bending, and shear forces are effects always present in this kind of measurement that affects sensor's response.…”
Section: Discussionmentioning
confidence: 99%
“…For example, a challenging task is the monitoring of pressure exerted by a backpack on the shoulders and on the back of the user [8,10], which is complicated by the uncontrollability of the strap-shoulder interface and by user movements [11]. Several research works address this issue to extract meaningful information having an impact on ergonomy [2] or user posture [9,12].…”
Section: Introductionmentioning
confidence: 99%
“…The F-scan pressure sensors (Hsiao et al 2002, Wettenschwiler et al, 2015 were used during the test to balance the load between the left and right feet. At that time, the standing pressure patterns were collected as well.…”
Section: Discussionmentioning
confidence: 99%
“…Many efforts have been made to alleviate the negative effect when carrying a backpack, particularly by improving the pressure distribution over the body. The static pressures caused by the shoulder straps may cause local fatigue of the superior trapezius, but the hip region was more tolerant to static pressures [5][6][7][8]. Many packs have added components such as the hip belt, chest strap, load lifters to help even the pressure distribution.…”
Section: Introductionmentioning
confidence: 99%