HPLC–DAD–FLD Determination of Veterinary Pharmaceuticals in Pharmaceutical Industry Wastewater with Precolumn Derivatization Using Fluorescamine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
10
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(11 citation statements)
references
References 29 publications
1
10
0
Order By: Relevance
“…The performance of the developed method was compared with that from previous studies (Table ). As for HPLC–FLD detection for SA analysis, the sensitivity levels recorded in this study were in the same order of those determined using other extraction methods such as in situ derivatization by pyridine/acetic anhydride and HF‐LPME , in situ derivatization by fluorescamine and IL‐based MADLLME , and SPE with precolumn derivatization by fluorescamine . Regarding the applied HF‐LPME method, the LOQs of SAs in our study were slightly lower than those without derivatization in previous studies .…”
Section: Resultssupporting
confidence: 83%
See 3 more Smart Citations
“…The performance of the developed method was compared with that from previous studies (Table ). As for HPLC–FLD detection for SA analysis, the sensitivity levels recorded in this study were in the same order of those determined using other extraction methods such as in situ derivatization by pyridine/acetic anhydride and HF‐LPME , in situ derivatization by fluorescamine and IL‐based MADLLME , and SPE with precolumn derivatization by fluorescamine . Regarding the applied HF‐LPME method, the LOQs of SAs in our study were slightly lower than those without derivatization in previous studies .…”
Section: Resultssupporting
confidence: 83%
“…The most widely used detection method equipped with LC for SAs quantification is MS/MS . Additionally, diode array detection (DAD) , UV detection , and fluorescence detection (FLD) are frequently used. DAD and UV detectors are common but their sensitivities are limited; by contrast, MS/MS is efficient and sensitive but also expensive .…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…More generally, pharmaceuticals move into the sewage system and to waste water treatment plants [10]. The nutrition-rich sewage sludge and compost can be used as fertilizers for plants.…”
Section: Introductionmentioning
confidence: 99%