1981
DOI: 10.1016/0013-4694(81)90188-7
|View full text |Cite
|
Sign up to set email alerts
|

Human cerebral potentials evoked by moving dynamic random DOT stereograms

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

1986
1986
2016
2016

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(8 citation statements)
references
References 9 publications
0
8
0
Order By: Relevance
“…With other stereoscopic patterns, Kimura et al [24] also observed a negative wave at 180 ms but not the conventional VEP components (N75, P100, N140). Other authors [5,11] using dynamic RDS found a late negative response after 180 ms and 250 ms. An explanation of why the conventional components of the "monocular" pattern VEP are not present in the S-VEP is unclear, but stimulus conditions and positions of the recording electrodes could explain it. In several subjects, a positive onset response of variable amplitude could be found at 120 ms, followed by the negative component.…”
Section: Discussionmentioning
confidence: 95%
“…With other stereoscopic patterns, Kimura et al [24] also observed a negative wave at 180 ms but not the conventional VEP components (N75, P100, N140). Other authors [5,11] using dynamic RDS found a late negative response after 180 ms and 250 ms. An explanation of why the conventional components of the "monocular" pattern VEP are not present in the S-VEP is unclear, but stimulus conditions and positions of the recording electrodes could explain it. In several subjects, a positive onset response of variable amplitude could be found at 120 ms, followed by the negative component.…”
Section: Discussionmentioning
confidence: 95%
“…Published results show differences in the latencies and the number of the peaks recorded. The reported results consist of studies that obtained monophasic (Regan and Spekreijse 1970;Julesz et al 1980;Julesz and Kropfl 1982;Oguchi and Mashima 1989), biphasic (Regan and Beverley 1973;Fukai 1985;Fenelon et al 1986;Skrandies 1987;Chao et al 1988;Manning et al 1992;Janssen et al 1999) and triphasic (Mol and Caberg 1977;Herpers et al 1981;Yanashima et al 1987) waveforms. Besides the results in which the peaks are localized within a time interval of 100-200 ms (Regan and Spekreijse 1970;Fukai 1985;Skrandies 1987;Yanashima et al 1987;Oguchi and Mashima 1989), there are also results that consist of peaks within a wide 100-to 600-ms time window (Mol and Caberg 1977).…”
Section: Introductionmentioning
confidence: 85%
“…Dynamic, as opposed to static, random dot stereograms (RDS) and stereopatterns have been used in a number of laboratories (Mol and Caberg, 1977;Herpers, Caberg and Mol, 1981;Lehmann and Julesz, 1978;Breitmeyer et al, 1974). The authors have developed a display system for RDS intended for use with orthoptic patients as well as with normals and have published a series of technical and applied evoked response studies (Neill and Fenelon, 1981 ;Neill et al, 1982;Dunlop et al, 1983;Manning, 1984a, 1984b).…”
Section: Introductionmentioning
confidence: 99%