2020 IEEE 18th World Symposium on Applied Machine Intelligence and Informatics (SAMI) 2020
DOI: 10.1109/sami48414.2020.9108765
|View full text |Cite
|
Sign up to set email alerts
|

Human ECG data collection, digitalization, streaming and storing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 9 publications
0
3
0
Order By: Relevance
“…Type Format [17,38,42,50,[58][59][60] XML-ECG Yes Open [61] HL7-XML Yes Open [27] mPCG-XML Yes Open [62,63] Philips-XML No Propietary [64,65] ecgML No Open [14,66] mECGML Yes Open [53,67] JSON Yes Open [17] SaECG Yes Open [49,68] HL7 aECG Yes Open [52,69] CDA R2 Yes Open [67] PDF-ECG Yes Open [70][71][72] MFER No Propietary [73] EDF No Open [74] CSV Yes Open [75] ECGWARE No Open…”
Section: Studies Data Formats Mhealth Interoperabilitymentioning
confidence: 99%
“…Type Format [17,38,42,50,[58][59][60] XML-ECG Yes Open [61] HL7-XML Yes Open [27] mPCG-XML Yes Open [62,63] Philips-XML No Propietary [64,65] ecgML No Open [14,66] mECGML Yes Open [53,67] JSON Yes Open [17] SaECG Yes Open [49,68] HL7 aECG Yes Open [52,69] CDA R2 Yes Open [67] PDF-ECG Yes Open [70][71][72] MFER No Propietary [73] EDF No Open [74] CSV Yes Open [75] ECGWARE No Open…”
Section: Studies Data Formats Mhealth Interoperabilitymentioning
confidence: 99%
“…In the previous research presented in the literature, many problems have been detected regarding ECG monitoring, such as the problems related to the digitalization and storage of stream-like long ECG recordings that are collected from long-term ambulatory sensors or devices [32]. A framework and a real solution for all the steps involved in ECG monitoring, from data collection from single-channel ECG sensors and digitalization to data storing, were introduced in [33]. Furthermore, we have presented a new enhanced version of the Health Level Seven International (HL7) Fast Healthcare Interoperability Resources (FHIR) data format, named HL7-aECG.…”
Section: Related Workmentioning
confidence: 99%
“…This feature can effectively mine the potential information in the existing data and improve the behavior recognition rate. Researchers based on sensor behavior recognition mainly solve the problem of system energy consumption from two aspects [20][21][22]. First, by improving the system recognition architecture, reducing the energy consumption in the entire behavior recognition process, and in terms of commercial applications, improving the information transmission method to meet the demand for low power consumption.…”
Section: Introductionmentioning
confidence: 99%