2022
DOI: 10.1016/j.jtcvs.2021.11.085
|View full text |Cite
|
Sign up to set email alerts
|

HVAD to HeartMate 3 left ventricular assist device exchange: Best practices recommendations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 33 publications
0
9
0
Order By: Relevance
“…The size and shape of apical and outflow sensors were chosen based on the diameter of a typical LVAD apical cuff and sealed outflow graft. 17,19 The iterative optimization procedure described in 20 was used to optimize the sensors in terms of turns, outer diameter, wire thickness, wire spacing, and pitch at an operating frequency of 13.56 MHz in ANSYS Electronics Desktop 2021 R2. We used copper wire for winding and polyamide as the top layer to make it biocompatible.…”
Section: Methodsmentioning
confidence: 99%
“…The size and shape of apical and outflow sensors were chosen based on the diameter of a typical LVAD apical cuff and sealed outflow graft. 17,19 The iterative optimization procedure described in 20 was used to optimize the sensors in terms of turns, outer diameter, wire thickness, wire spacing, and pitch at an operating frequency of 13.56 MHz in ANSYS Electronics Desktop 2021 R2. We used copper wire for winding and polyamide as the top layer to make it biocompatible.…”
Section: Methodsmentioning
confidence: 99%
“…The Medtronics HeartWare HVAD (Figure 4) was approved by FDA in November of 2012 for BTT. It has been implanted in more than 20,000 heart failure patients worldwide, with one HVAD being implanted for greater than 7 years [1,22]. The HVAD functions via both passive magnetic levitation and a hydrodynamic bearing system [22].…”
Section: Hvadmentioning
confidence: 99%
“…It has been implanted in more than 20,000 heart failure patients worldwide, with one HVAD being implanted for greater than 7 years [1,22]. The HVAD functions via both passive magnetic levitation and a hydrodynamic bearing system [22]. In June of 2021, the sale and implantation of the HVAD was discontinued secondary to technical issues with the device not restarting after planned or accidental power disconnection.…”
Section: Hvadmentioning
confidence: 99%
“…110 Other types of implantable vascular assist devices include the Heartmate 3 LVAD, Heartware left ventricular assist device (HVAD), and Heartmate II LVAD. 111 Coyle et al demonstrated that Heartmate 3 had a lower risk of cardiac arrhythmias, pump thrombosis, and infection compared with HVAD; however, they did not differ significantly in outcomes such as survival and quality of life. 112 HVAD has also been associated with a higher risk of stroke and gastrointestinal bleeding.…”
Section: Managementmentioning
confidence: 99%