Fifth International Conference on Trends in Distribution Switchgear: 400v-145kV for Utilities and Private Networks 1998
DOI: 10.1049/cp:19980759
|View full text |Cite
|
Sign up to set email alerts
|

Hybrid current limiting interrupting device for 3-phase 400 V AC applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
2
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…In 1998, a hybrid current-limiting interrupting device (HCLID) was proposed by experts at the Technical University of Gdansk, Gdansk, Poland. The structure of the HCLID is simple: a mechanical contact, two diode and two thyristors, together with an L-C series-connected circuit [31,32]. As seen in Figure 11, the HCLID may inject a countercurrent into the main path to provide zero-crossing conditions.…”
Section: Cl-cbs With Inductor-capacitor (L-c) Componentsmentioning
confidence: 99%
“…In 1998, a hybrid current-limiting interrupting device (HCLID) was proposed by experts at the Technical University of Gdansk, Gdansk, Poland. The structure of the HCLID is simple: a mechanical contact, two diode and two thyristors, together with an L-C series-connected circuit [31,32]. As seen in Figure 11, the HCLID may inject a countercurrent into the main path to provide zero-crossing conditions.…”
Section: Cl-cbs With Inductor-capacitor (L-c) Componentsmentioning
confidence: 99%
“…The resulted impedance is resistive so that the fault current is in phase with the voltage [17]. The experts in Technical University of Gdansk proposed their hybrid current-limiting interrupting device (HCLID) in 1998, with the configuration of L-C counter current injection circuit [29,30], as shown in Fig. 11.…”
Section: Current-limiting Circuit Breakers With L-c Componentsmentioning
confidence: 99%
“…Łącznik stanowi aparat zaliczany do rodziny ograniczników prądu FCL (ang. Fault Current Limiter), których działanie polega na szybkim i samoczynnym włączaniu do obwodu zwarciowego reaktancji w układzie jednofazowym lub trójfazowym [2,3,5]. Inne znane i od lat rozwijane techniki FCL polegają m.in.…”
Section: Wstępunclassified
“…W pełni tyrystorowy wyłącznik ograniczający [5] powstał jako rozwinięcie idei układu hybrydowego, w którym funkcje ograniczania i przerywania prądu były rozdzielone. Wyłącznik hybrydowy o strukturze szeregowej z dwoma dławikami ograniczającymi [2] opracowano na Wydziale Elektrycznym Politechniki Gdańskiej. Podjęta tematyka wpisuje się w widoczny od szeregu lat trend stosowania półprzewodnikowej aparatury FCL [8].…”
Section: Wstępunclassified
See 1 more Smart Citation