2018
DOI: 10.1051/matecconf/201814703007
|View full text |Cite
|
Sign up to set email alerts
|

Hydraulic and Groundwater Chemical Parameters of the Aquifer in Malakasari, Bandung

Abstract: Abstract. In order to reveal the physical condition of the aquifer, the pumping test using Cooper-Jacob (1946) principle has conducted at well SM5. The observation data of the test then processed to generate various value of hydraulic properties i.e. 3.241x10-4 cm 2 /sec for transmissivity (T), 8.103x10-6 cm/sec for conductivity (K), 0.05055 for storativity (S), and 3.852x10-3 ft -1 for specific storage (Ss). These data show that the aquifer composed of unconsolidated sedimentary rocks ranged from coarse san… Show more