2002
DOI: 10.1016/s0021-9673(01)01583-7
|View full text |Cite
|
Sign up to set email alerts
|

Hypercross-linked polystyrene and its potentials for liquid chromatography: a mini-review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
42
0
2

Year Published

2005
2005
2023
2023

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 96 publications
(44 citation statements)
references
References 15 publications
0
42
0
2
Order By: Relevance
“…Hypercrosslinked polymers are a new 107 generation of permanently porous, polymeric resins with enhanced analyte 108 retention characteristics arising from their high micropore contents and 109 correspondingly high specific surface areas (>1000 m 2 g -1 ) [13]. Recently, we 110 disclosed the synthesis of mixed-mode hypercrosslinked sorbents with weak 111 6 Darmstadt, Germany).…”
mentioning
confidence: 99%
“…Hypercrosslinked polymers are a new 107 generation of permanently porous, polymeric resins with enhanced analyte 108 retention characteristics arising from their high micropore contents and 109 correspondingly high specific surface areas (>1000 m 2 g -1 ) [13]. Recently, we 110 disclosed the synthesis of mixed-mode hypercrosslinked sorbents with weak 111 6 Darmstadt, Germany).…”
mentioning
confidence: 99%
“…These therapies are based on nonspecifi c mechanisms such as hydrophobic interactions [10] and size exclusion [30] . Treatment for DRA consists primarily of symptomatic relief via anti-infl ammatory drugs, pain killers, surgery, use of ultrapurifi ed dialysate, and implementation of highly permeable and biocompatible membranes during the kidney replacement therapy [8,[44][45][46] to reduce the blood concentration of ␤ 2 m. The membrane properties that are important for ␤ 2 m removal during dialysis include permeability, adsorptive capacity and biocompatibility.…”
Section: Discussionmentioning
confidence: 99%
“…This adsorbent column is based on proprietary hyper cross-linked styrene divinylbenzene co-polymer beads. The bead's pore size (2-20 Å) is suffi cient to remove molecules in the molecular weight range of 0.3-15.0 kDa [28][29][30] , a range which includes a broad spectrum of so called middle molecular weight toxins [11,26,27,31,32] . In August 2002, the device was entered into clinical trials in the USA.…”
mentioning
confidence: 99%
“…В этой связи мы попытались улучшить технологию SPE, заменив LiChroprep RP-18 на полимерный сорбент на основе сверхсшитого полистирола (Purosep-200). Этот отечественный сорбент обладает рядом уникальных свойств: сорбционная ёмкость в несколько раз превышает таковую у силикагеля, выдерживает рН от 0 до 14,0, одинаково эффективно сорбирует полярные и неполярные соединения, как из воды, так и из некоторых органических растворителей [4][5][6]. Кроме того, был заменен дериватизационный реагент -взамен ранее использовавшегося фенацил бромида, был апробирован 1-(бромоацетил)пирен, который ранее для этой цели не использовался [7].…”
unclassified