Hypodermic-Needle-Like Hollow Polymer Microneedle Array: Fabrication and Characterization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
26
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 32 publications
(26 citation statements)
references
References 24 publications
0
26
0
Order By: Relevance
“…1b ). This tip geometry has been shown to minimize the force required for skin penetration, making it similar to that of a conventional 26-gauge hypodermic needle 25 . Microneedles are configured in a 4 × 4, two-dimensional array to increase the rate of sample extraction, with a needle-to-needle spacing of 2 mm (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…1b ). This tip geometry has been shown to minimize the force required for skin penetration, making it similar to that of a conventional 26-gauge hypodermic needle 25 . Microneedles are configured in a 4 × 4, two-dimensional array to increase the rate of sample extraction, with a needle-to-needle spacing of 2 mm (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…A discontinuity in the detected force in the graph indicated the fractured threshold force for the microneedle, which was also confirmed by visual observation during the test. By testing 100 microneedles from 10 MFS devices, the average buckling force was as much as 1.92N ± 0.16N, It was much larger than the minimal required penetration force (less than 0.5 N) for the microneedles with similar geometry and dimension [38], which proved that the fabricated microneedles were strong enough to penetrate skin surface.…”
Section: B Stiffness Testing and Penetration Testing For Mfsmentioning
confidence: 97%
“…Hollow microneedles have been developed to allow the transfer of a drug from a reservoir within the patch to the microcirculation and can enable volumes of up to 200 μL to be transported. In many respects, the system mimics the operation of a conventional hypodermic syringe [ 42 , 48 , 49 , 50 , 51 ]. It must be noted that hollow needle fabrication is significantly more complex and those possessing a high aspect ratio lack the internal support structure common to solid needles, leading to potential failure if improperly inserted.…”
Section: The Quest For Needle-free Deliverymentioning
confidence: 99%