BACKGROUND: Ex vivo normothermic limb perfusion (EVNLP) preserves amputated limbs under near-physiologic conditions. Perfusates containing red blood cells (RBCs) have shown to improve outcomes during ex vivo normothermic organ perfusion, when compared with acellular perfusates. To avoid limitations associated with the use of blood-based products, we evaluated the feasibility of EVNLP using a polymerized hemoglobin-based oxygen carrier-201 (HBOC-201).
METHODS:Twenty-four porcine forelimbs were procured from Yorkshire pigs. Six forelimbs underwent EVNLP with an HBOC-201-based perfusate, six with an RBC-based perfusate, and 12 served as static cold storage (SCS) controls. Ex vivo normothermic limb perfusion was terminated in the presence of systolic arterial pressure of 115 mm Hg or greater, fullness of compartments, or drop of tissue oxygen saturation by 20%. Limb contractility, weight change, compartment pressure, tissue oxygen saturation, oxygen uptake rates (OURs) were assessed. Perfusate fluid-dynamics, gases, electrolytes, metabolites, methemoglobin, creatine kinase, and myoglobin concentration were measured. Uniformity of skin perfusion was assessed with indocyanine green angiography and infrared thermography.
RESULTS:Warm ischemia time before EVNLP was 35.50 ± 8.62 minutes (HBOC-201), 30.17 ± 8.03 minutes (RBC) and 37.82 ± 10.45 (SCS) ( p = 0.09). Ex vivo normothermic limb perfusion duration was 22.5 ± 1.7 hours (HBOC-201) and 28.2 ± 7.3 hours (RBC) ( p = 0.04). Vascular flow (325 ± 25 mL•min −1 vs. 444.7 ± 50.6 mL•min −1 ; p = 0.39), OUR (2.0 ± 1.45 mL O 2 •min −1 •g −1 vs. 1.3 ± 0.92 mL O 2 •min −1 •g −1