1999
DOI: 10.1107/s0021889898007717
|View full text |Cite
|
Sign up to set email alerts
|

SIR97: a new tool for crystal structure determination and refinement

Abstract: SIR97 is the integration of two programs, SIR92 and CAOS, the ®rst devoted to the solution of crystal structures by direct methods, the second to re®nement via least-squares±Fourier procedures. Several new features have been introduced in SIR97 with respect to the previous version, SIR92: greater automatization, increased ef®ciency of the direct methods section, and a powerful graphics interface. The program also provides publication tables and CIF ®les.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

16
6,409
1
19

Year Published

2000
2000
2007
2007

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 9,696 publications
(6,501 citation statements)
references
References 16 publications
16
6,409
1
19
Order By: Relevance
“…www.chemeurj.org Crystal structure determinations: X-ray intensities were measured on a Nonius KappaCCD diffractometer with rotating anode and graphite monochromator (l = 0.71073 ). The structures were solved with automated Patterson Methods [34] (compounds 7, 12 a, 14, 16 b, 21 a, and 28 a) or Direct Methods [35] (compound 17 a) and refined with SHELXL-97 [36] on F 2 of all reflections. Geometry calculations, drawings and checking for higher symmetry were performed with the PLATON [37] package.…”
Section: Resultsmentioning
confidence: 99%
“…www.chemeurj.org Crystal structure determinations: X-ray intensities were measured on a Nonius KappaCCD diffractometer with rotating anode and graphite monochromator (l = 0.71073 ). The structures were solved with automated Patterson Methods [34] (compounds 7, 12 a, 14, 16 b, 21 a, and 28 a) or Direct Methods [35] (compound 17 a) and refined with SHELXL-97 [36] on F 2 of all reflections. Geometry calculations, drawings and checking for higher symmetry were performed with the PLATON [37] package.…”
Section: Resultsmentioning
confidence: 99%
“…X-ray crystallography: X-ray intensities for complexes 2-4 were collected by using a Nonius-Kappa CCD diffractometer with rotating anode. The structures were solved by using direct methods (compound 2 with SHELXS-97, [50] compound 4 with SIR-97) [51] or automated Patterson methods (compound 3, DIRDIF-99), [52] and refined with SHELXL-97 [53] against F 2 of all reflections. Non-hydrogen atoms were refined freely with anisotropic displacement parameters.…”
Section: Methodsmentioning
confidence: 99%
“…The structure was solved by direct methods (SIR97). 70 All calculations were performed with the XTAL system. 71 Full-matrix least-squares refinement based on F using weights of 1/(σ 2 (Fo) + 0.00015(Fo 2 )) gave final values R ) ωR ) 0.037, and S ) 1.84(4) for 176 variables and 1516 contributing reflections.…”
Section: Methodsmentioning