2010
DOI: 10.1111/j.1939-165x.2010.00214.x
|View full text |Cite
|
Sign up to set email alerts
|

Identification of neoplastic cells in blood using the Sysmex XT‐2000iV: a preliminary step in the diagnosis of canine leukemia

Abstract: Using a novel gating strategy the Sysmex XT-2000iV may be used effectively to screen canine blood for hematopoietic neoplasia.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

2
7
0

Year Published

2012
2012
2017
2017

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 18 publications
2
7
0
Order By: Relevance
“…In addition, the overall relative rat bone marrow differential counts obtained in the studies here are comparable to ranges established over the past 10 years using the antibody‐specific flow cytometric method. Also, gating of blasts within the bone marrow 5‐part differential count was consistent with a previous report of blast identification using the Sysmex platform in peripheral blood of dogs with leukemia . Most importantly, once established, gating can be consistently used without further adjustment, although a certain expertise and training with the Sysmex instrument is required.…”
Section: Discussionsupporting
confidence: 87%
“…In addition, the overall relative rat bone marrow differential counts obtained in the studies here are comparable to ranges established over the past 10 years using the antibody‐specific flow cytometric method. Also, gating of blasts within the bone marrow 5‐part differential count was consistent with a previous report of blast identification using the Sysmex platform in peripheral blood of dogs with leukemia . Most importantly, once established, gating can be consistently used without further adjustment, although a certain expertise and training with the Sysmex instrument is required.…”
Section: Discussionsupporting
confidence: 87%
“…Although flow cytometry can be rapid and informative and may provide a very high likelihood of lymphoma and even phenotype, it is unable to provide a diagnosis of specific lymphoma subtype. 9,18,25 The practice of lymphoma diagnosis in human medicine is solidly based on histology, and this practice needs to be followed in veterinary oncology as well. Currently, most lymphoma therapy in animals is largely palliative, suggesting that collaboration is needed with oncologists to test specific protocols on single subtypes of lymphoma with a goal of therapy that is closer to curative.…”
Section: Discussionmentioning
confidence: 99%
“…The Sysmex XT‐2000iV is a recent hematology analyzer that combines impedance and optical methods and for which specific veterinary software has been developed. The analyzer has been used in veterinary medical research and has been validated for use in dogs . Reference intervals (RIs) aid in the interpretation of laboratory results by characterizing normal fluctuations observed in a healthy population, and have only recently been established for dogs using the Sysmex analyzer .…”
Section: Introductionmentioning
confidence: 99%