2020 28th Iranian Conference on Electrical Engineering (ICEE) 2020
DOI: 10.1109/icee50131.2020.9260705
|View full text |Cite
|
Sign up to set email alerts
|

Identifying the Voltage Sags Vulnerability Area with Considering FACTS Devices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 17 publications
0
6
0
Order By: Relevance
“…When the fault occurs, voltages of some lines and buses reaches values lower than its voltage threshold. The area includes of these lines and buses is considered as the area of vulnerability related to voltage sag [25]. Results of fault analysis for line to line fault is shown in Table I and Table II.…”
Section: Faultsmentioning
confidence: 99%
“…When the fault occurs, voltages of some lines and buses reaches values lower than its voltage threshold. The area includes of these lines and buses is considered as the area of vulnerability related to voltage sag [25]. Results of fault analysis for line to line fault is shown in Table I and Table II.…”
Section: Faultsmentioning
confidence: 99%
“…Another method for estimating voltage sags has been proposed in [22] which is costly and needs a very long period of time to achieve accurate results. Hence, authors in [1] and [23] have developed a systematic method for assessing and estimating the voltage sags performance in the absence and presence of alternating current transmission system (FACTS) devices. This method can be used for both radial and large meshed networks and its main advantages are the fast response, low cost and accurate result in investigating voltage sags performance [24].…”
Section: Voltage Sag Definition and Estimationmentioning
confidence: 99%
“…Capacitor units in the structures of [21], [23]- [25], can be charged up to DC source value. Therefore, they have the same problems like unipolar generators.…”
Section: Introductionmentioning
confidence: 99%
“…In [26], a unipolar/bipolar structure has been introduced, in which a buck-boost converter is utilized for charging the capacitors up to several times of the DC source voltage. Also, different power quality issues like voltage sag can be reduced by the method proposed in [25]. This structure exploits two inductors as energy storage, one for positive pulses generation and another one for negative pulses generation [27].…”
Section: Introductionmentioning
confidence: 99%