2015
DOI: 10.1016/j.isatra.2015.08.014
|View full text |Cite
|
Sign up to set email alerts
|

IM Direct Torque Control with no flux distortion and no static torque error

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
16
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 26 publications
(18 citation statements)
references
References 26 publications
1
16
0
Order By: Relevance
“…In DTC, the accuracy of electromagnetic torque and stator flux estimation is very important to ensure satisfactory performance [34,46]. So, several parameters must be determined, the stator current is measured while the stator voltage depends on the switching state (S a , S b and S c ) produced by the switching table and the DC link voltage U dc [47].…”
Section: Direct Torque Controlmentioning
confidence: 99%
“…In DTC, the accuracy of electromagnetic torque and stator flux estimation is very important to ensure satisfactory performance [34,46]. So, several parameters must be determined, the stator current is measured while the stator voltage depends on the switching state (S a , S b and S c ) produced by the switching table and the DC link voltage U dc [47].…”
Section: Direct Torque Controlmentioning
confidence: 99%
“…Actually, in the stationary reference frame (α, β)s, it is possible to achieve stator flux control through hysteresis controllers as detailed in [28]. The diagram of the DRFOC could be illustrated as given by figure 3, where, Table I presents the switching table and the two chosen controllers are shown respectively in figures 4 and 5.…”
Section: Elimination Of the Pwm Generatormentioning
confidence: 99%
“…In fact, according to the effect brought by each voltage vector to the stator flux components in the (α, β)s reference frame, a switching table I is summarized as follow [28]: Eφsα =1 (Eφsβ=1) means that φsα (φsβ) should increase, Eφsα =-1 (Eφsβ=-1 ) means that φsα (φsβ) should decrease, and Eφsβ =0 means that φsβ should be kept unchanged. While Hφsα and Hφsβ represent respectively the half of the desired φsα and φsβ hysteresis bounds.…”
Section: Elimination Of the Pwm Generatormentioning
confidence: 99%
See 1 more Smart Citation
“…However, DTC is a more popular and widely adopted choice due to various reasons, explored by researchers. [22][23][24][25][26][27] The effect of such voltage disturbance condition can be catastrophic for multiphase drives, implemented for sensitive applications. Thus, a proper control function with an appropriate converter configuration for such drive systems accounting the mitigation of such adverse supply effects is of prime importance.…”
mentioning
confidence: 99%