2018
DOI: 10.3389/fncom.2017.00118
|View full text |Cite
|
Sign up to set email alerts
|

Image Processing for Bioluminescence Resonance Energy Transfer Measurement—BRET-Analyzer

Abstract: A growing number of tools now allow live recordings of various signaling pathways and protein-protein interaction dynamics in time and space by ratiometric measurements, such as Bioluminescence Resonance Energy Transfer (BRET) Imaging. Accurate and reproducible analysis of ratiometric measurements has thus become mandatory to interpret quantitative imaging. In order to fulfill this necessity, we have developed an open source toolset for Fiji—BRET-Analyzer—allowing a systematic analysis, from image processing t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
4

Relationship

4
4

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 15 publications
0
6
0
Order By: Relevance
“…Single-cell BRET imaging. Single-cell BRET imaging experiments were performed and analyzed as previously described (35,64,65). Briefly, hippocampal neurons in culture were cotransfected at DIV10 to 12 either with plasmids coding for the Nluc-tagged donor together with the Venus-tagged acceptor or with plasmids coding for the donor only and DsRed as a transfection reporter.…”
Section: Discussionmentioning
confidence: 99%
“…Single-cell BRET imaging. Single-cell BRET imaging experiments were performed and analyzed as previously described (35,64,65). Briefly, hippocampal neurons in culture were cotransfected at DIV10 to 12 either with plasmids coding for the Nluc-tagged donor together with the Venus-tagged acceptor or with plasmids coding for the donor only and DsRed as a transfection reporter.…”
Section: Discussionmentioning
confidence: 99%
“…Acquired emission images were analyzed on ImageJ (version 1.53h). Stacked images were aligned using the Linear Stack with Alignment with SIFT plugin and then analyzed using the BRET-Analyzer plugin (Chastagnier et al 2017). mNeonGreen images were used to generate FA masks using a machine learning tool, Ilastik (version 1.3.2).…”
Section: Image Analysismentioning
confidence: 99%
“…For BRET between mGlu5 and Homer and for AIMTOR biosensor, we sequentially exposed the donor 10 s and the acceptor 20 s. For ERK biosensor, we sequentially exposed the donor 5 s and the acceptor 10 s. BRET was measured in each field every 2 or 3 minutes. Analysis was performed as previously described (31). Briefly,…”
Section: Bret Measurementsmentioning