Imaging lungs using inert fluorinated gases

Abstract: Rat lungs were imaged by 19F projection MRI of hexafluoroethane, mixed with 20% oxygen to form the inhaled gas. The 3D image had 700 microm resolution, and the data took 4.3 h to acquire. Free induction decays were collected in the presence of steady magnetic field gradients in 686 different directions. To take advantage of fast relaxation (T1 = 5.9 +/- 0.2 ms), the repetition time was 5 ms. To eliminate signal loss from magnetic field inhomogeneities, data were collected within 2 ms of spin excitation (from 8… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

2
118
0
2

Year Published

1999
1999
2012
2012

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 119 publications
(122 citation statements)
references
References 26 publications
2
118
0
2
Order By: Relevance
“…This was achieved by making use of the gradient overdrive of the MR scanner, leading to particularly short gradient ramps by using nonlinear data sampling during the sinusoidal gradient ramps and by using an asymmetric echo. Although the TE achieved with this approach is still significantly longer than that achievable with projection reconstruction pulse sequences (12,22), we obtained sufficient SNR for an ROI evaluation of the MR images. A further advantage of our approach is the fact that image reconstruction can be performed by the conventional fast Fourier transform technique, while projection reconstruction algorithms used in other studies (12,13) may be difficult to implement on some clinical MR systems.…”
Section: Fig 4 Amentioning
confidence: 89%
See 3 more Smart Citations
“…This was achieved by making use of the gradient overdrive of the MR scanner, leading to particularly short gradient ramps by using nonlinear data sampling during the sinusoidal gradient ramps and by using an asymmetric echo. Although the TE achieved with this approach is still significantly longer than that achievable with projection reconstruction pulse sequences (12,22), we obtained sufficient SNR for an ROI evaluation of the MR images. A further advantage of our approach is the fact that image reconstruction can be performed by the conventional fast Fourier transform technique, while projection reconstruction algorithms used in other studies (12,13) may be difficult to implement on some clinical MR systems.…”
Section: Fig 4 Amentioning
confidence: 89%
“…However, the wash-in of these aerosols critically depends on the size of the aerosol particles (i.e., on the production of the aerosol), which limits quantitative applications of this method as well. Further approaches comprise fluorine-19 ( 19 F) MRI either of 19 F-containing fluids (9,10) or of inert fluorinated gases in the lung (11,12). Whereas the first of these two 19 F MRI approaches has been demonstrated in animals and, most probably, will have a limited role in humans, the second one is of particular interest for human applications.…”
mentioning
confidence: 99%
See 2 more Smart Citations
“…Diese Gase besitzen sehr kurze T 1 -Relaxationszeiten im Millisekundenbereich, so dass die geringe Spindichte der Gase durch eine groûe Anzahl von Signalmittelungen kompensiert werden kann [6]. Allerdings war in bisherigen Arbeiten die Messzeit in der Gröûenordnung von Stunden, so dass diese Technik bisher nicht für die Anwendung am Menschen eingesetzt werden konnte [6,7].…”
Section: Introductionunclassified