2015
DOI: 10.1016/j.snb.2014.10.014
|View full text |Cite
|
Sign up to set email alerts
|

Immunoassay of cardiac biomarkers using a photodiode array biochip

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 38 publications
0
6
0
Order By: Relevance
“…Han et al have made use of this relationship in the development of a photodiode array biochip by using a NHS-LC-Biotin kit as a means to create biotinylated Abs. The formation of this detection probe was dependent on the binding of the biotinylated Abs with streptavidin conjugated AuNPs [74]. The biosensor utilised both monoclonal and polyclonal Abs in the sandwich-based immunoassay, although more significantly, the biotinylated strategy employed produces randomly orientated Abs.…”
Section: Immobilisation Strategiesmentioning
confidence: 99%
See 1 more Smart Citation
“…Han et al have made use of this relationship in the development of a photodiode array biochip by using a NHS-LC-Biotin kit as a means to create biotinylated Abs. The formation of this detection probe was dependent on the binding of the biotinylated Abs with streptavidin conjugated AuNPs [74]. The biosensor utilised both monoclonal and polyclonal Abs in the sandwich-based immunoassay, although more significantly, the biotinylated strategy employed produces randomly orientated Abs.…”
Section: Immobilisation Strategiesmentioning
confidence: 99%
“…Figure 3 and Figure 4: [37,38,48,49,50,57,58,61,65,66,68,69,70,71,74,84,85,86,87,88,89,93,94,95,96,97,104,105,111,112,115,116,117,120,121,122,123,125,126,127,128,130,132,133,134,136,138,144,145,148,150,151,159,161,174,175,176,184,185,186,187,188,189,190,…”
Section: Reprinting Figuresmentioning
confidence: 99%
“…Thanks to the development of the silicon solid-state photoelectric technology, photosensitive devices such as photodiodes (PDs) [6,7], PD array (PDA) chips [8], and silicon photomultipliers (SiPMs) [9,10] have been produced with micro-packaging and high sensitivity, which fit the requirement for the miniaturized ECL instrument [6][7][8][9][10]. The SiPM, also called multi-pixel photon counter (MPPC), is a new type of photon-counting device made up of multiple avalanche PD (APD) pixels operated in Geiger mode [11].…”
Section: Introductionmentioning
confidence: 99%
“…Immunogold labeling technique has been widely used to amplify analytical signal for bio-recognition applications similar to horseradish peroxidase (HRP) in ELISA due to the high electron density of gold nanoparticles (AuNps) as well as the further signal amplification through immunogold silver staining [17][18][19][20][21][22]. Guo et al showed the good prospect of immunogold assay in real clinical applications by reducing an assay time to 40 min which is much faster than the traditional ELISA that takes usually at least 3 h for a turnaround test [23].…”
Section: Introductionmentioning
confidence: 99%
“…However, the detection limit of the assay for cTnI sensing in serum samples was still limited to be 1 ng/mL similar to those detected by ELISA, requiring a more sensitive immunoassay procedure or sensor platform. Recently, many studies were reported to improve the sensitivity of the immunogold-based assay for the detection of cardiac markers by using different sensor platforms such as a surface acoustic wave immunosensor [24], electrochemical immunosensors [16], photodiode array [20], and colorimetric assay [25]. The previously reported immunogold assays were achieved by a direct assay where the immunoreaction between the target antigen and the mab-cTnI coated on the well undergoes in advance.…”
Section: Introductionmentioning
confidence: 99%