2021
DOI: 10.1007/s00417-020-05046-3
|View full text |Cite
|
Sign up to set email alerts
|

Impact of measured total keratometry versus anterior keratometry on the refractive outcomes of the AT TORBI 709-MP toric intraocular lens

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…29 In our study, the Goniotrans application was used to allow reference the angular position of the IOL axis on an image of the eye. Likewise, the ZCALC calculator was used that have been shown to provide reliable and accurate refractive outcomes in toric IOL calculation, 30,31 introducing some adjustments to consider the potential contribution of posterior corneal astigmatism to total corneal astigmatism. Furthermore, IOL reposition was always performed in those cases showing a clinically significant level of IOL rotation in the early postoperative period.…”
Section: Discussionmentioning
confidence: 99%
“…29 In our study, the Goniotrans application was used to allow reference the angular position of the IOL axis on an image of the eye. Likewise, the ZCALC calculator was used that have been shown to provide reliable and accurate refractive outcomes in toric IOL calculation, 30,31 introducing some adjustments to consider the potential contribution of posterior corneal astigmatism to total corneal astigmatism. Furthermore, IOL reposition was always performed in those cases showing a clinically significant level of IOL rotation in the early postoperative period.…”
Section: Discussionmentioning
confidence: 99%
“…The newer IOLMaster 700 obtains a reading of total corneal power, taking both corneal thickness and actual values for the radius of the posterior cornea into account, using telecentric 3-zone K and swept-source OCT technology. By replacing hypotheses and modeling with actual measurements, the IOLMaster 700 may provide reliable data on corneal power in some challenging cases, such as surgically modified [ 7 , 28 , 29 , 34 ] and high astigmatic corneas [ 17 , 35 , 36 ]. Here, we found no significant difference between TK and standard K in highly myopic eyes within this certain range of corneal thickness.…”
Section: Discussionmentioning
confidence: 99%
“…This total keratometry value is most likely composed from the corneal front and back surface data in addition to the central corneal thickness using some upgraded version of the Gullstrand formula for spherocylindrical surfaces. The first studies on the total keratometry value provided by the IOLMaster 700 show that these data seem to be a good indicator for calculation of toric intraocular lenses (Levron et al 2021), but further studies with a larger study population have to proof the potential of total keratometry especially for toric lens power calculations.…”
Section: Discussionmentioning
confidence: 99%
“…The first studies on the total keratometry value provided by the IOLMaster 700 show that these data seem to be a good indicator for calculation of toric intraocular lenses (Levron et al. 2021), but further studies with a larger study population have to proof the potential of total keratometry especially for toric lens power calculations.…”
Section: Discussionmentioning
confidence: 99%