2012
DOI: 10.1186/2110-5820-2-28
|View full text |Cite
|
Sign up to set email alerts
|

Impact of physical incompatibility on drug mass flow rates: example of furosemide-midazolam incompatibility

Abstract: BackgroundPatients in intensive care units receive many drugs simultaneously but through limited venous accesses. Several intravenous therapies have to be administered through the same catheter, thus increasing the risk of physicochemical incompatibility. The purpose of this work was to assess and to quantify the impact of physical incompatibility on the mass flow rates of drugs infused simultaneously to the patient, through an in vitro study.MethodsFurosemide-midazolam incompatibility was used to assess the i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
12
0
4

Year Published

2013
2013
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 27 publications
(16 citation statements)
references
References 11 publications
0
12
0
4
Order By: Relevance
“…However, in recent years, ample evidence has been found [14], including a number of clinical cases and in vivo studies [59], indicating that physical effects related to the infusion hardware are equally important to understand [10, 11]. Especially in critical care, on the ICU and the OR, where multiple medications are typically delivered through one single lumen of a thin catheter, these physical effects may cause ambiguous and counter-intuitive discrepancies between the intended dose and the dose that has been actually delivered.…”
Section: Introductionmentioning
confidence: 99%
“…However, in recent years, ample evidence has been found [14], including a number of clinical cases and in vivo studies [59], indicating that physical effects related to the infusion hardware are equally important to understand [10, 11]. Especially in critical care, on the ICU and the OR, where multiple medications are typically delivered through one single lumen of a thin catheter, these physical effects may cause ambiguous and counter-intuitive discrepancies between the intended dose and the dose that has been actually delivered.…”
Section: Introductionmentioning
confidence: 99%
“…1,2 Incompatibility sometimes induces various undesirable reactions, including precipitation, color change, drug degradation, and yield of toxic products upon covalent binding. 3 These factors might jeopardize the safety and effectiveness of intravenous drug therapies. 4 According to the clinical case, famotidine (FMT; Fig.…”
Section: Introductionmentioning
confidence: 99%
“…As mais escassas, como já mencionadas, são as que investigam sua frequência no âmbito hospitalar (6,7,(17)(18)(19)(20)(21)(22)(23)(24)(25)(26)(27)(28)(29) . Entretanto, testes laboratoriais entre medicamentos e pesquisas que visam à segurança do paciente também foram desenvolvidos (30)(31)(32)(33)(34)(35)(36)(37)(38)(39) .…”
Section: Introdução 20 Julia Helena Garciaunclassified
“…Ações voltadas para o uso racional de medicamentos e a padronização de infusões são também incorporadas com o objetivo de garantir o sucesso da terapêutica (56,57) . O desenvolvimento de dispositivos, como os adaptadores multilúmens, filtros de linhas, cateteres com maiores distância entre os lúmens ou com mais vias (de três a cinco vias) é importante aliado na prevenção de incompatibilidades (37,38,43) .…”
Section: Introdução 22 Julia Helena Garciaunclassified
See 1 more Smart Citation