2010 IEEE Asia-Pacific Conference on Applied Electromagnetics (APACE) 2010
DOI: 10.1109/apace.2010.5720085
|View full text |Cite
|
Sign up to set email alerts
|

Impact of SAR on human head modeling in Elevators using IFA

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 4 publications
0
3
0
Order By: Relevance
“…Many studies on the SAR value of a single antenna for mobile handsets have been carried out in different frequency bands [13][14][15][16][17][18][19][20][21][22][23][24][25][26]. In [27], an investigation of the SAR caused by two-element antenna array at 1.9 GHz has been reported and it was shown that the SAR value reaches a maximum when the phase difference is near 180 degrees and a minimum when the phase difference is approximately 0 degree.…”
Section: Introductionmentioning
confidence: 99%
“…Many studies on the SAR value of a single antenna for mobile handsets have been carried out in different frequency bands [13][14][15][16][17][18][19][20][21][22][23][24][25][26]. In [27], an investigation of the SAR caused by two-element antenna array at 1.9 GHz has been reported and it was shown that the SAR value reaches a maximum when the phase difference is near 180 degrees and a minimum when the phase difference is approximately 0 degree.…”
Section: Introductionmentioning
confidence: 99%
“…EM exposure within metallic environments is, also, a topic of great interest because of the multiple wave reflections occurring inside or near them. The averaged SAR values can be increased inside metallic enclosures compared to free space [33][34][35] and at the presence of metallic walls [36,37]. Whole-body exposure assessment might be equally significant with the peak averaged SAR values in the head at fully and partially enclosed metallic elevator cabins [38,39].…”
Section: Introductionmentioning
confidence: 99%
“…Modeling only human head, some additional papers have studied the effects from metallic walls and full metallic enclosures of small size (much smaller than the size of a proper elevator cabin). They have shown that SAR values are increased in the full enclosures as compared to the free space [5,6]. Also when antenna is tilted 45 degrees from its initial position the SAR 10g is increased [7].…”
Section: Introductionmentioning
confidence: 99%