2014
DOI: 10.1016/j.medici.2014.11.007
|View full text |Cite
|
Sign up to set email alerts
|

Impedance plethysmography as an alternative method for the diagnosis of peripheral arterial disease

Abstract: Impedance plethysmography, especially its parameter CT, is an alternative noninvasive method in diagnosing PAD and could be used for the screening of patients with PAD.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 24 publications
0
4
0
1
Order By: Relevance
“…Threshold pulse wave amplitude of 0.06% dR (resistance change due to blood volume change) and 0.60% dR/s for systolic slope were used [ 36 ]. When compared to ABI diagnosed PVD in a study of 66 patients, a sensitivity of 73.2% and a specificity of 96% was reported, using crest time thresholds of 180 ms [ 61 ].…”
Section: Plethysmographic Methodsmentioning
confidence: 99%
“…Threshold pulse wave amplitude of 0.06% dR (resistance change due to blood volume change) and 0.60% dR/s for systolic slope were used [ 36 ]. When compared to ABI diagnosed PVD in a study of 66 patients, a sensitivity of 73.2% and a specificity of 96% was reported, using crest time thresholds of 180 ms [ 61 ].…”
Section: Plethysmographic Methodsmentioning
confidence: 99%
“…If sphincter insufficiency is caused by damage or stretching of the pudendal nerve (neurogenic damage), with preserved continuity, conservative treatment should be applied. Patients with symptoms of fecal incontinence, whether caused by sphincter injury or neurogenic damage, should undergo intensive treatment [27][28][29][30][31][32]. In case of absence of proper treatment for sphincter trauma detected in the postpartum period, extended reconstructive surgery performed by an experienced colorectal surgeon can be necessary.…”
Section: Gradementioning
confidence: 99%
“…Metode lain yang digunakan untuk mengukur nilai ABI untuk mendeteksi PAD yaitu menggunakan impedansi plethysmography untuk mengukur sirkulasi darah di pergelangan kaki. Sensitivitas pengukuran ABI dengan teknik ini sebesar 73% dan spesifisitas sebesar 96% [9]- [10]. Penggunaan osillometric juga digunakan untuk mengukur ABI pada pasien normal yang memiliki risiko penyakit kardiovaskular dengan sensitivitas 0.71 dan spesifitisitas sebesar 0.89 [11].…”
Section: Pendahuluanunclassified