2008
DOI: 10.1002/elan.200704100
|View full text |Cite
|
Sign up to set email alerts
|

Impedance Study of GaN and InGaN Semiconductor Anion Selective Electrodes

Abstract: The response of potentiometric anion selective electrodes employing undoped GaN or In 0.2 Ga 0.8 N films as sensing element to detect various anions was investigated in solutions of KF, KNO 3 , KCl, HOC 6 H 4 COONa, KSCN, CH 3 COOK, KClO 4 and KBr salts. The calibration plots for the GaN and In 0.2 Ga 0.8 N semiconductor electrodes contained linear regions extending over four decades of activity change in most solutions. The structure of the GaN and In 0.2 Ga 0.8 N semiconductor electrode/ electrolyte interfac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 15 publications
0
6
0
Order By: Relevance
“…The carrier/acceptor concentration in the samples was provided by the supplier of the samples and verified by electrochemical impedance spectroscopy (EIS) measurements. [34][35][36] EIS was used as a technique capable of providing information for carrier concentration for both nanorods 34 and thin films, 35 unlike Hall measurements which could be used only for thin films. EIS was performed in a three-electrode cell.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The carrier/acceptor concentration in the samples was provided by the supplier of the samples and verified by electrochemical impedance spectroscopy (EIS) measurements. [34][35][36] EIS was used as a technique capable of providing information for carrier concentration for both nanorods 34 and thin films, 35 unlike Hall measurements which could be used only for thin films. EIS was performed in a three-electrode cell.…”
Section: Methodsmentioning
confidence: 99%
“…The electrolyte used was carbonate propylene (0.1 M LiClO 4 ) and 0.1 M KCl for ZnO and p-GaN, respectively. 34,35 All EIS data were obtained using CH Instruments electrochemical workstation and the analysis was done by commercial software from CH Instruments. For ZnO, 20 mV sinusoidal signal was applied with constant dc bias, with frequency ranging from 500 kHz and 5 mHz.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The electrochemical performance of the IrO 2 -based electrodes was characterized using cyclic voltammetry (CV), chronopotentiometry (CP) and electrochemical impedance spectroscopy (EIS). A three-electrode cell system and a Solartron analytical SI 1287 system coupled with a Solartron analytical 1252A frequency response analyzer were used [30]. The prepared IrO 2 -based electrodes were used as working electrodes.…”
Section: Electrode Preparation and Characterizationmentioning
confidence: 99%