The response of potentiometric anion selective electrodes employing undoped GaN or In 0.2 Ga 0.8 N films as sensing element to detect various anions was investigated in solutions of KF, KNO 3 , KCl, HOC 6 H 4 COONa, KSCN, CH 3 COOK, KClO 4 and KBr salts. The calibration plots for the GaN and In 0.2 Ga 0.8 N semiconductor electrodes contained linear regions extending over four decades of activity change in most solutions. The structure of the GaN and In 0.2 Ga 0.8 N semiconductor electrode/ electrolyte interface was studied through electrochemical impedance spectroscopy. Analogous equivalent circuits modeling the GaN or In 0.2 Ga 0.8 N electrode/electrolyte interface were proposed and their parameters were calculated. The space charge layer of the GaN and In 0.2 Ga 0.8 N semiconductors dominated the impedance of the electrochemical system at high frequencies (> 10 kHz), whereas at low frequencies (< 10 kHz), the impedance was controlled by the diffusion of electroactive species across the layer of adsorbed ions at the surface of the electrode. Results imply a strong dependence of the electrodes performance on the adsorption capacity of tested anions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.