2022
DOI: 10.1088/1361-651x/ac6b4a
|View full text |Cite
|
Sign up to set email alerts
|

Implementing a non-local lattice particle method in the open-source large-scale atomic/molecular massively parallel simulator

Abstract: Using conventional continuum-based simulation frameworks to model crack initiation and extension can be computationally challenging. As an alternative to continuum-based approaches, particle-based simulation methods are well-suited to handle the discontinuities present during fracture propagation. A well-known particle-based method is the lattice particle method (LPM), which discretizes the system into a set of interconnected particles ollowing a periodic arrangement. Discontinuities can be handled simply by r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 46 publications
0
2
0
Order By: Relevance
“…Polymerization Reaction Process. First, the initial configuration is relaxed using the conjugate gradient (CG) algorithm, 23 and the energy of the model is minimized in LAMMPS 24 to obtain a balanced and homogeneous initial model, which makes the geometry of the system more optimized. Throughout the simulation, the model used a time step of 0.25 fs, starting at 300 K and equilibrating the system for 50 ps at NVT (constant volume and constant temperature), followed by a heating treatment to place the geopolymer in the aging phase, where the temperature of the system was raised to 1500 K at a rate of 6 K/ps to eliminate any memory effects.…”
Section: Methodsmentioning
confidence: 99%
“…Polymerization Reaction Process. First, the initial configuration is relaxed using the conjugate gradient (CG) algorithm, 23 and the energy of the model is minimized in LAMMPS 24 to obtain a balanced and homogeneous initial model, which makes the geometry of the system more optimized. Throughout the simulation, the model used a time step of 0.25 fs, starting at 300 K and equilibrating the system for 50 ps at NVT (constant volume and constant temperature), followed by a heating treatment to place the geopolymer in the aging phase, where the temperature of the system was raised to 1500 K at a rate of 6 K/ps to eliminate any memory effects.…”
Section: Methodsmentioning
confidence: 99%
“…The LAMMPS (Large-scale Atomic/Molecular Massively Parallel Simulator, version 22 August 2018) [ 37 ] was used to perform simulations using all of the selected models [ 38 , 39 ]. It is one of the most commonly used simulators in many fields of science.…”
Section: Methodsmentioning
confidence: 99%