2010
DOI: 10.1016/j.aca.2010.07.005
|View full text |Cite
|
Sign up to set email alerts
|

Imprinted sol–gel materials for monitoring degradation products in automotive oils by shear transverse wave

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
29
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 31 publications
(29 citation statements)
references
References 14 publications
0
29
0
Order By: Relevance
“…The MISGs were prepared according to approaches reported by Lieberzeit et al [29,33,35,36,39]. TiO 2 -based MISGs were prepared by dissolving 50 μL of template molecules in 2 mL of isopropanol.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The MISGs were prepared according to approaches reported by Lieberzeit et al [29,33,35,36,39]. TiO 2 -based MISGs were prepared by dissolving 50 μL of template molecules in 2 mL of isopropanol.…”
Section: Methodsmentioning
confidence: 99%
“…The MISGs-coated QCM electrodes were dried at 130 ℃ for 1h. This process has been reported enough to not only remove the templates from the layer materials but also produce smooth surface [36]. After that, the electrodes were then kept in vacuum at room temperature before the vapor sensing.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A variety of sensor devices have been proposed to monitor the degradation based on different parameters such as viscosity [3], conductivity [4], and acidity [5]. Further improvements were carried out by introducing molecular recognition properties in sensitive layers to determine the chemical quality of engine oil in gas or liquid phase by employing mass sensitive transducers [68]. Recently, dielectric spectroscopy has also been employed to detect the age of used engine oil [9].…”
Section: Introductionmentioning
confidence: 99%
“…Thus, the acoustic wave devices are considered as universal mass-sensitive or gravimetric transducers. These transducers include: (a) the bulk acoustic wave devices such as quartz crystal microbalance (QCM) [28,29]; (b) the surface acoustic wave (SAW) resonators [30,31]; and (c) the shear transverse wave (STW) resonators [32,33], which are frequently studied in a combination with different receptor materials for molecular recognition and biomedical diagnosis. The mass-sensitive biosensors produce direct shift in frequency in the event of receptor-analyte interaction and analyte recognition.…”
Section: Introductionmentioning
confidence: 99%