2001
DOI: 10.1016/s0021-9290(00)00166-4
|View full text |Cite
|
Sign up to set email alerts
|

Improved accuracy and reliability of sweepback angle, pitch angle and hand velocity calculations in swimming

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
26
0
17

Year Published

2003
2003
2015
2015

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 37 publications
(43 citation statements)
references
References 7 publications
0
26
0
17
Order By: Relevance
“…For the calculations, hand model angles of attack of 0°, 15°, 30°, 45°, 60°, 75°, and 90°, with a sweep back angle of 0° (thumb as the leading edge) were used (Schleihauf, 1979). Steady-state CFD analyses were performed using the Fluent code, and the drag and lift coefficients were calculated for a flow velocity of 2.0 m·s -1 (Lauder et al, 2001;Rouboa et al, 2006). We used the segregated solver with the standard K-epsilon turbulence model because this turbulence model was shown to be accurate with measured values in previous research (Moreira et al, 2006).…”
Section: Cfd Studymentioning
confidence: 99%
“…For the calculations, hand model angles of attack of 0°, 15°, 30°, 45°, 60°, 75°, and 90°, with a sweep back angle of 0° (thumb as the leading edge) were used (Schleihauf, 1979). Steady-state CFD analyses were performed using the Fluent code, and the drag and lift coefficients were calculated for a flow velocity of 2.0 m·s -1 (Lauder et al, 2001;Rouboa et al, 2006). We used the segregated solver with the standard K-epsilon turbulence model because this turbulence model was shown to be accurate with measured values in previous research (Moreira et al, 2006).…”
Section: Cfd Studymentioning
confidence: 99%
“…Lauder, et al 65 previously reported the smallest frame found in a swimming related study, measuring just 0.4 m 3 (1.0 m x 0.5 m x 0.8 m). These studies focused on specific aspects of swimmer's arm movements and the relationship of these with propulsion.…”
Section: 63mentioning
confidence: 84%
“…38,55-57, 65 Payton, et al 57 used a frame measuring 1.3 m x 0.93 m x 0.88 m (1.06 m 3 ) and digitized six anatomical landmarks on the shoulder, forearm and hand in order to determine the movements of one arm during a single stroke. Lauder, et al 65 previously reported the smallest frame found in a swimming related study, measuring just 0.4 m 3 (1.0 m x 0.5 m x 0.8 m).…”
Section: 63mentioning
confidence: 99%
See 1 more Smart Citation
“…Angles of attack of hand models of 0º, 15º, 30º, 45º, 60º, 75º and 90º, with a sweep back angle of 0º (thumb as the leading edge) were used for the calculations (Schleihauf, 1979). Steady-state analyses were performed using the Fluent ® code and the drag and lift coefficients were calculated for a flow velocity of 2.0 m/s (Lauder et al, 2001;Rouboa et al, 2006). We used the segregated solver with the standard k-epsilon turbulence model because this turbulence model was shown to be accurate with measured values in a previous research (Moreira et al, 2006).…”
Section: Simulationsmentioning
confidence: 99%