1999
DOI: 10.1002/(sici)1521-3838(199910)18:4<329::aid-qsar329>3.0.co;2-v
|View full text |Cite
|
Sign up to set email alerts
|

Improved Alignment by Weighted Field Fit in CoMFA of Histamine H2 Receptor Agonistic Imidazolylpropylguanidines

Abstract: More realistic description of ligand-receptor interactions in CoMFA results from alignments considering surface and ®eld properties instead of only molecular frameworks. The ®eld ®t algorithm implemented in SYBYL (Tripos Ass.) as part of the energy minimizer provides the possibility to assign individual weights to grid points. A new weighting function derives the signi®cance of grid points for the alignment of ®elds from preceding CoMFA runs, using regression coef®cients, means, and standard deviations of ®eld… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2001
2001
2017
2017

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 10 publications
0
9
0
Order By: Relevance
“…3). The best pharmacophore was selected based on previous studies [15,16,22,23] and the following QSAR indicators. As illustrated in Fig.…”
Section: Optimal Pharmacophore Selectionmentioning
confidence: 94%
See 2 more Smart Citations
“…3). The best pharmacophore was selected based on previous studies [15,16,22,23] and the following QSAR indicators. As illustrated in Fig.…”
Section: Optimal Pharmacophore Selectionmentioning
confidence: 94%
“…From the superposition of the agonists with the pharmacophore, there were no pharmacophore features mapping to the chiral centre in alkyl side chains, so the chirality of the compounds were ignored. The chirality was also neglected in pervious 3D-QSAR study on the H 2 agonists [15,16], and experiments also demonstrated that ␣ or ␤ position chirality played minor role in H 2 activation [48]. When PLS factor was set as 3, the best QSAR model was obtained with R 2 = 0.90 for the training set and Q 2 = 0.66 for the test set (Fig.…”
Section: Qsar Activity Predictionmentioning
confidence: 99%
See 1 more Smart Citation
“…Similar weights were assigned to all grid points, although improved results with individual weighting were reported. 60 Subsequently, applying the rigid realignment procedure produced alignments C2 and C3. Finally, an unconstrained energy minimization was used to relax every molecule from internal strain, producing alignment C4.…”
Section: Alignment As Basis Of 3d-qsarmentioning
confidence: 99%
“…The use of the routine has been reported by several workers (see, e.g., [33][34][35]) but is quite complex in operation [36], involving the inclusion of weighted field-fit energy penalties as additional parameters in the Tripos force field. More recently, Paretti et al have described a procedure that is analogous to that reported here [20] but that uses Monte Carlo and simplex procedures for the generation of the alignments, rather than a GA, and PLS analysis of N×N similarity matrices, rather than CoMFA and CoMSIA.…”
Section: Discussionmentioning
confidence: 99%