2012
DOI: 10.1007/s10096-012-1676-9
|View full text |Cite
|
Sign up to set email alerts
|

Improved diagnosis of central venous catheter-related bloodstream infections using the HB&L UROQUATTRO™ system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 29 publications
0
3
0
Order By: Relevance
“…The instrument allows only for detection of live bacteria, because the initial blank value reading eliminates inert materials. The system was previously evaluated for microorganism enrichment, determination of microbial count, and diagnosis of central venous catheter-related bloodstream infections [ 18 , 19 ]. Alfred 60AST was initially conceived for urine screening and for AST of bacterial isolates from urine [ 20 ].…”
Section: Introductionmentioning
confidence: 99%
“…The instrument allows only for detection of live bacteria, because the initial blank value reading eliminates inert materials. The system was previously evaluated for microorganism enrichment, determination of microbial count, and diagnosis of central venous catheter-related bloodstream infections [ 18 , 19 ]. Alfred 60AST was initially conceived for urine screening and for AST of bacterial isolates from urine [ 20 ].…”
Section: Introductionmentioning
confidence: 99%
“…Microbiological Approach in Diagnosing Native and Heart Valves Prosthesis Infections in a liquid media using HB&L Culture Kit vial (Alifax, Padova Italy) also supplemented with HB&L DEB Kit (Alifax) in order to guarantee the growth of the fastidious microorganism. Vials were incubated on SIDECAR automated system (Alifax) for 6 h. The SIDECAR is the automated version of HB&L together with the ALFRED system and it is also based on laser light scattering nephelometer technology [16,17]. At the end of the instrumental protocol, specimens were seeded onto a set of different media (all provided by bioMeriux; Marcy l'Etoile.…”
Section: Research Papermentioning
confidence: 99%
“…Since 1980s nephelometry based systems, which detect scattered light intensity changes in time due to microorganisms division, are used for direct determination of viable microorganisms in urine samples [6] . Uro-Quick (Alifax) and BacterioScan 216Dx (BacterioScan Inc.) systems allow not only to perform bacteriuria screening, but also to test bacterial cultures for antibiotic susceptibility [7] , [8] , [9] , [10] . For bacteriuria screening, the analyzed parameter is growth delay time after start of incubation: in the case of significant bacteriuria, fast growth is observed, in the case of contamination, growth is delayed for a few hours.…”
Section: Introductionmentioning
confidence: 99%