2016
DOI: 10.1049/iet-gtd.2015.0753
|View full text |Cite
|
Sign up to set email alerts
|

Improved equal current approach for reference current generation in shunt applications under unbalanced and distorted source and load conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
14
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(14 citation statements)
references
References 18 publications
0
14
0
Order By: Relevance
“…Thus, the reactive reference grid current components are obtained by using (20) and unit quadrature vectors calculated in (15)- (17) as…”
Section: Computation Of Reactive Reference Grid Current Componentsmentioning
confidence: 99%
See 1 more Smart Citation
“…Thus, the reactive reference grid current components are obtained by using (20) and unit quadrature vectors calculated in (15)- (17) as…”
Section: Computation Of Reactive Reference Grid Current Componentsmentioning
confidence: 99%
“…Singh and Solanki [15] have discussed comparative performance of three different methods, namely IRP theory, SRF theory and adaline based to derive reference currents. Recent control approaches based on adaptive repetitive control [16], predictive current control [17], Wiener filter [18], Gauss-Newton-based controller [19], and improved equal current approach [20] have also been developed by several researchers.…”
Section: Introductionmentioning
confidence: 99%
“…However, in the secondary distribution system (voltages less than 2.3 kV), usage of MLI for DSTATCOM applications is not a cost-effective option. This is because, it requires more number of switches and higher control complexity compared to the two-level inverter [16,17]. Finally, FL-DSTATCOM is suitable for both 3P3W and 3P4W systems, however, it requires two additional switches compared to three-leg and TPSC DSTATCOM.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, in order to overcome the drawbacks of above control schemes and to explore the capabilities of ES-1, this paper discusses and proposes a modified instantaneous symmetrical component algorithm (ISCA)-based control to operate ES-1 as an APF and to explore its functional capabilities. Among the different reference current generation algorithm [19][20][21][22][23][24][25][26], ISCA is used due to its simple formulation and ability to work under any source and load conditions [26]. Further, the switching sequence of inverter is generated using hysteresis current tracking controller utilising the reference currents generated by modified ISCA to nullify currentbased issues and simultaneously achieving voltage regulation using single multifunctional control.…”
Section: Introductionmentioning
confidence: 99%