2016
DOI: 10.1016/j.apenergy.2016.09.089
|View full text |Cite
|
Sign up to set email alerts
|

Improved in situ performance testing of line-concentrating solar collectors: Comprehensive uncertainty analysis for the selection of measurement instrumentation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…The uncertainty of the data logger is not included in the sensor uncertainties. If data logger uncertainties were to be added by users of this dataset, it is recommended to set them in the range of ±0.10% - 0.15% of the measured value (uniform distribution), as these values have been used for similar setups [19] .…”
Section: Experimental Design Materials and Methodsmentioning
confidence: 99%
“…The uncertainty of the data logger is not included in the sensor uncertainties. If data logger uncertainties were to be added by users of this dataset, it is recommended to set them in the range of ±0.10% - 0.15% of the measured value (uniform distribution), as these values have been used for similar setups [19] .…”
Section: Experimental Design Materials and Methodsmentioning
confidence: 99%
“…Zirkel-Hofer et al [6] An article discussing the selection and installation of measurement devices based on uncertainty examination of different sensors (focusing on concentrating collectors).…”
Section: Faure Et Al [4]mentioning
confidence: 99%
“…The ambient temperature is also a crucial measurement, as it allows for estimating heat losses of collectors [4][5][6], storages [16], and pipes [16]. Please note that multiple sensors might be needed if the temperature is different at different places of interest (e.g., collector arrays in the field versus pipes inside the control room).…”
Section: Ambient Measurements (Weather Station)mentioning
confidence: 99%
“…The efficiency testing conditions for thermal performance test under quasi-dynamic conditions are referred to the international standard ISO 9806 [4] new revision, made in 2018, which consider the large-size PTC. In some references from Fraunhoher [5,6] the in-situ methodology was presented, using dynamic method (DT). In a previous study [7], a large-size PTC array has been tested at the Plataforma Solar de Almeria (PSA) using a collector installed in East-West orientation and studying particularly the goodness of the quasi-dynamic (QDT) methodology.…”
Section: Introductionmentioning
confidence: 99%