Improved Measurement of the Low-Frequency Complex Permeability of Ferrite Annulus for Low-Noise Magnetic Shielding

Abstract: The ferrite magnetic shield can provide a low-noise magnetic environment for various ultrahigh-sensitivity measurements. The low-frequency complex permeability, which determines the magnetic hysteresis noise and the shielding factor, is a key parameter of the ferrite shield and thus should be measured accurately. In this paper, the measurement error of conventional coil method is analyzed at low frequency, and an improved method is proposed which could eliminate the measurement error introduced by the wire res… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
10
0

Year Published

2020
2020
2025
2025

Publication Types

Select...
10

Relationship

2
8

Authors

Journals

citations
Cited by 20 publications
(11 citation statements)
references
References 25 publications
1
10
0
Order By: Relevance
“…The complex permeability (µ = µ − iµ ) was measured using the impedance measurement method [10], [22]- [24]. This method has been demonstrated in the research on the ferrite shield in [10] and [24]. A toroidal coil with 16 turns was wound over the lid (shown in Fig.…”
Section: B Permeability Electrical Resistivity and Shielding Factormentioning
confidence: 99%
“…The complex permeability (µ = µ − iµ ) was measured using the impedance measurement method [10], [22]- [24]. This method has been demonstrated in the research on the ferrite shield in [10] and [24]. A toroidal coil with 16 turns was wound over the lid (shown in Fig.…”
Section: B Permeability Electrical Resistivity and Shielding Factormentioning
confidence: 99%
“…Therefore, there is inevitable magnetic noise. The magnetic noise of the common mu-metal magnetic shield is mainly dominated by Johnson magnetic noise : Where: is the relative magnetic conductivity; k is the Boltzmann constant; T is the temperature; σ is the conductivity; t is the thickness of the magnetic shield; r is the radius of the magnetic shield; G is a constant related to the aspect ratio of magnetic shielded shapes [17][18][26][27]. As shown in FIGURE.2, the alkali metal gas chamber is the core component of the SERF magnetometer.…”
Section: B Magnetic Noise Analysismentioning
confidence: 99%
“…In the impedance measurement method, an impedance analyzer (LCR-meter) is used to obtain the resistance and inductance of the coil wound around the toroidal permalloy, allowing for the calculation of its complex permeability. Based on this method, Yang et al [20] used a linear fitting method to separate the wire resistance from the measured resistance. This not only eliminated the measurement error in imaginary permeability at low frequencies but also enhanced the accuracy of the impedance measurement method.…”
Section: Introductionmentioning
confidence: 99%