Improved Method for the ASTM Platelet and Leukocyte Assay: Use of Minimal Heparinization in a Screening Test for Hemocompatibility of Blood-Contacting Medical Devices

Abstract: Most blood-contacting medical devices must be assessed for potential thrombogenicity prior to regulatory approval. A common assay for screening and qualifying devices involves monitoring the reduction of platelet and leukocyte (P&L) counts in whole blood exposed to the device. We have validated an improved method for assessing a device's effect on platelet activation and surface adhesion, offering significant improvement over the current ASTM F2888-13 method, which uses blood fully anticoagulated by acidif… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 8 publications
1
2
0
Order By: Relevance
“…However, the difference was more pronounced for 1 U/ml, suggesting a greater test sensitivity for thrombogenicity evaluation at the lower heparin concentration. Our platelet count results using low‐dose heparin are consistent with a recent study by Schatz et al, 16 in which 1 U/ml heparin anticoagulation substantially improved test sensitivity for discriminating between materials when compared to sodium citrate anticoagulation. Using a heparin concentration below 1 U/ml is not recommended for this assay as pretest blood clot formation was already observed at 1 U/ml heparin for a small portion (< 10%) of blood donors, and the pretest clotting rate would be higher at a lower heparin concentration.…”
Section: Discussionsupporting
confidence: 90%
“…However, the difference was more pronounced for 1 U/ml, suggesting a greater test sensitivity for thrombogenicity evaluation at the lower heparin concentration. Our platelet count results using low‐dose heparin are consistent with a recent study by Schatz et al, 16 in which 1 U/ml heparin anticoagulation substantially improved test sensitivity for discriminating between materials when compared to sodium citrate anticoagulation. Using a heparin concentration below 1 U/ml is not recommended for this assay as pretest blood clot formation was already observed at 1 U/ml heparin for a small portion (< 10%) of blood donors, and the pretest clotting rate would be higher at a lower heparin concentration.…”
Section: Discussionsupporting
confidence: 90%
“…Careful fixation of blood is essential due to its instability. To ensure a reliable assessment of blood interaction with the tested material, appropriately low concentrations of anticoagulant and stabilizing agents have to be used 7 .…”
Section: Introductionmentioning
confidence: 99%
“…Careful xation of blood is essential due to its instability. To ensure a reliable assessment of blood interaction with the tested material, appropriately low concentrations of anticoagulant and stabilizing agents have to be used [7].…”
Section: Introductionmentioning
confidence: 99%