Improved sensitivity to fluorescence for cancer detection in wide-field image-guided neurosurgery

Abstract: In glioma surgery, Protoporphyrin IX (PpIX) fluorescence may identify residual tumor that could be resected while minimizing damage to normal brain. We demonstrate that improved sensitivity for wide-field spectroscopic fluorescence imaging is achieved with minimal disruption to the neurosurgical workflow using an electron-multiplying charge-coupled device (EMCCD) relative to a state-of-the-art CMOS system. In phantom experiments the EMCCD system can detect at least two orders-of-magnitude lower PpIX. Ex vivo t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
34
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 22 publications
(34 citation statements)
references
References 34 publications
0
34
0
Order By: Relevance
“…In fact, the food coloring consists of two dyes, namely tartrazine and allura red, which are known to be strong quenchers . We consider this an important observation as these phantoms are widely used for the calibration in spectroscopic imaging of PpIX in brain tumors and quenching might generate false estimations of PpIX concentration values. To still use these phantoms to calibrate spectrometric PpIX imaging devices the influence of the quenching needs to be predicted.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…In fact, the food coloring consists of two dyes, namely tartrazine and allura red, which are known to be strong quenchers . We consider this an important observation as these phantoms are widely used for the calibration in spectroscopic imaging of PpIX in brain tumors and quenching might generate false estimations of PpIX concentration values. To still use these phantoms to calibrate spectrometric PpIX imaging devices the influence of the quenching needs to be predicted.…”
Section: Resultsmentioning
confidence: 99%
“…Tissue phantoms composed of PpIX dimethly ester (CAS:5522‐66‐7; Sigma‐Aldrich, St. Louis, Missouri) dissolved in dimethyl sulfoxide (DMSO), lipid emulsion (Intralipid 20%), distilled water and yellow food coloring (McCormick) were generated based on the study of Jermyn et al These phantoms are state of the art for the calibration of spectroscopic and hyperspectral PpIX imaging devices . The lipid emulsion simulated tissue scattering with μ s [cm −1 ] = {30, 35, 40, 45} while the yellow food color acted as absorber with μ a [cm −1 ] = {18, 30, 42, 50, 60} at 405 nm.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…6 We have developed several different platforms for quantitative PpIX FGR, i.e., to measure and map the absolute PpIX concentration, [PpIX], in tissue. [7][8][9] There are two main approaches: semiempirical correction for tissue attenuation, typically using a form of multiple-wavelength ratiometry, and rigorous correction based on independent measurements of the tissue absorption and scattering coefficients at the relevant wavelengths. This study is an extension of two previous developments.…”
Section: Introductionmentioning
confidence: 99%
“…This study is an extension of two previous developments. The first was the use of hyperspectral fluorescence imaging together with semiempirical correction algorithms 8,9 in which the use of a high-sensitivity electron-multiplying charge-coupled detector (EMCCD) enabled PpIX detection down to 10 ng∕ml in a glioma model. 9 The second development was based on an intraoperative quantitative point-contact fiber-optic spectroscopy probe 7 that has been shown in clinical trials to significantly improve the sensitivity and specificity of residual tumor tissue detection in high-grade glioma and to make FGR of a low-grade tumor feasible in patients.…”
Section: Introductionmentioning
confidence: 99%