1996
DOI: 10.1016/s0196-0644(96)70291-3
|View full text |Cite
|
Sign up to set email alerts
|

Improved Specificity of Myoglobin Plus Carbonic Anhydrase Assay Versus That of Creatine Kinase-MB for Early Diagnosis of Acute Myocardial Infarction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
4
1

Year Published

1997
1997
2007
2007

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 36 publications
(6 citation statements)
references
References 25 publications
1
4
1
Order By: Relevance
“…Accordingly, H-FABP showed the lowest − LH (0.18), and cTnI showed the highest + LH (24.64). In our study, the MYO/CA III best cutoff (1.73) had a higher sensitivity (MYO/CA III = 78.6% vs. MYO = 71.4%) but a lower specificity (MYO/CA III = 83.3% vs. MYO = 94.4%) than MYO, differently from the data reported in different papers [20][21][22][23][24]. Table 4 shows results obtained after combining the most specific marker (cTnI) with each one of the other markers studied, and evaluating the sensitivity and specificity of these different "two-marker strategies".…”
Section: Resultscontrasting
confidence: 99%
See 1 more Smart Citation
“…Accordingly, H-FABP showed the lowest − LH (0.18), and cTnI showed the highest + LH (24.64). In our study, the MYO/CA III best cutoff (1.73) had a higher sensitivity (MYO/CA III = 78.6% vs. MYO = 71.4%) but a lower specificity (MYO/CA III = 83.3% vs. MYO = 94.4%) than MYO, differently from the data reported in different papers [20][21][22][23][24]. Table 4 shows results obtained after combining the most specific marker (cTnI) with each one of the other markers studied, and evaluating the sensitivity and specificity of these different "two-marker strategies".…”
Section: Resultscontrasting
confidence: 99%
“…Several papers have shown the utility of combining CA III with MYO measurements in the presence of high plasma MYO concentrations: the plasma MYO/CA III ratio may indicate the tissue source of MYO, thus enhancing the specificity of MYO and confirming a diagnosis of AMI [20][21][22][23], also in patients with renal failure [24].…”
Section: Introductionmentioning
confidence: 99%
“…[12][13][14] Since skeletal and cardiac muscle myoglobins are indistinguishable, increased skeletal muscle myoglobin release due to a variety of medical conditions or lack of adequate renal clearance may cause a ''false-positive'' myoglobin test. 39,40 Indeed, our results confirm that the specificity of myoglobin (81.9% [95% CI = 38.6 to 62.9]) for the prediction of AEs is significantly lower than that of either cTnT (93.1% [95% CI = 90.3 to 95.8]) or CK-MB (99.7% [95% CI = 99.1 to 100.0]).…”
Section: The ''Clinical Specificity'' Of Myoglobinsupporting
confidence: 76%
“…Additional mark ers are emerging such as myoglobin, rapid CK-MB. and CK-MB isoforms as earlier markers of AMI than CK-MB mass [15][16][17][18], Assays for subunits of the troponin com plex using cardiac-specific antibodies have been reported as equally sensitive and possibly more specific than CK-MB for detecting acute myocardial injury [19. 21] in the presence of skeletal muscle damage [22][23][24],…”
Section: Discussionmentioning
confidence: 99%