Improved visualisation of choroidal neovascularisation by scanning laser ophthalmoscope using image averaging

Abstract: Aims: To improve visualisation of angiographic features in patients with age related macular degeneration associated with choroidal neovascularisation (CNV) and related complications. To evaluate if image averaging can achieve this goal. Methods: 27 eyes of 20 sequential patients with age related macular degeneration over a 3 month period were studied. Indocyanine green angiograms (ICGA), fluorescein angiograms (FA), and oral fluorescein angiograms were recorded with a confocal scanning laser ophthalmoscope. S… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 30 publications
(35 reference statements)
0
3
0
Order By: Relevance
“…The fundus images are obtained with a confocal scanning laser ophthalmoscope combined with the OCT system. Fundus autofluorescence images were recorded using Spectralis or a confocal Scanning Laser Ophthalmoscope (HRA2, Germany), the optical and technical principles of which have been described previously 15 16 17. The field size was selected as 30° × 30° at 1,536 × 1,536 pixels.…”
Section: Methodsmentioning
confidence: 99%
“…The fundus images are obtained with a confocal scanning laser ophthalmoscope combined with the OCT system. Fundus autofluorescence images were recorded using Spectralis or a confocal Scanning Laser Ophthalmoscope (HRA2, Germany), the optical and technical principles of which have been described previously 15 16 17. The field size was selected as 30° × 30° at 1,536 × 1,536 pixels.…”
Section: Methodsmentioning
confidence: 99%
“…9,10 Scanning laser ophthalmoscopy (SLO) is a confocal scanning laser microscopy for retinal or corneal imaging of the human eye. 11,12 The most recent introduced version of Spectralis (Heidelberg Engineering, Inc., Franklin, MA), a commercially available SLO system, has the ability to acquire both spectral domain-optical coherence tomography (SD-OCT), fluorescein angiography (FA), and the multicolor images of the retina by using three different wavelengths (infrared, green, and blue). This device offers a combination-pseudocolor-image by combining three wavelength images into a single image.…”
Section: Tear Film Evaluation By Scanning Laser Ophthalmoscopy Duringmentioning
confidence: 99%
“…In order to reduce the effect of the cornea reflections, different methods have been suggested, such as: (i) moving the lenses and mirrors in the interface optics off axis [13]; (ii) using a polarization beam splitter to eliminate specular reflections [14] and (iii) off-axis illumination of the retina so that the light coming back from the retina is along a different path than that followed by the back reflections [15]. However, all these methods present disadvantages, (i) leads to further aberrations, (ii) produces signal loss and dependence on the polarization of the sample whereas (iii) requires separation of imaging and WFS paths and two optical sources.…”
Section: Sensitivity To Stray Reflectionsmentioning
confidence: 99%