2014
DOI: 10.1016/j.matchar.2014.02.007
|View full text |Cite
|
Sign up to set email alerts
|

Improvement of adhesion and barrier properties of biomedical stainless steel by deposition of YSZ coatings using RF magnetron sputtering

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
6
0
1

Year Published

2015
2015
2022
2022

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 20 publications
(8 citation statements)
references
References 34 publications
0
6
0
1
Order By: Relevance
“…For the biomedical eld, however, this is an innovative subject with great possibilities which is now under extensive research. [27][28][29] In our study, TaN lm were fabricated on Ti6Al4V substrate by magnetron sputtering. The mechanical properties were characterized by employing the X-ray diffraction (XRD), X-ray Photoelectron Spectroscopy (XPS) and nanoindenter.…”
Section: Introductionmentioning
confidence: 99%
“…For the biomedical eld, however, this is an innovative subject with great possibilities which is now under extensive research. [27][28][29] In our study, TaN lm were fabricated on Ti6Al4V substrate by magnetron sputtering. The mechanical properties were characterized by employing the X-ray diffraction (XRD), X-ray Photoelectron Spectroscopy (XPS) and nanoindenter.…”
Section: Introductionmentioning
confidence: 99%
“…All samples showed an adherence strength between 28 and 30 MPa. These values are higher than those obtained by sol-gel YSZ on carbon steel (2.5-12.4 MPa) [17], as well as YSZ deposited by RF magnetron sputtering on 316 L stainless steel (12-26 MPa) [46]. The adhesion strength was even higher than some YSZ coatings produced by plasma spray, which reported values between 15 and 30 MPa [47][48][49].…”
mentioning
confidence: 62%
“…[1] to deposit YSZ and delay the corrosion of bare AISI 316L substrate is presented [2], [3], [4]. The Fig.…”
Section: Datamentioning
confidence: 99%
“…YSZ ceramic coatings were deposited on in a Tourus Kurt Lesker Coating System (1 × 10− 6 Pa) with argon chamber (20 sccm) at 50 mm (substrate-target distance) from 50 to 250 W and 30 to 120 min [1].Experimental featuresBare AISI 316 stainless steel substrate and YSZ sputtered on AISI 316L substrate were analyzed.Data source locationCICATA IPN Unidad Altamira, Tamaulipas, México.Data accessibilityMendeley Data https://doi.org/10.17632/k2njhtt479.3Related research articleZ.E. Sánchez-Hernández, M.A.…”
mentioning