2005
DOI: 10.1109/tpwrd.2004.838641
|View full text |Cite
|
Sign up to set email alerts
|

Improvement of Power Quality Using Adaptive Shunt Active Filter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
101
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 160 publications
(101 citation statements)
references
References 12 publications
0
101
0
Order By: Relevance
“…Shunt active filter is employed to control the inverter pulses. Sliding mode controller is proposed in this paper, which is a non-linear control method to suppress harmonics [16] and reactive power compensation to improve power quality [2]. Shunt active filter with SVC FACTS devices implemented using Sliding Mode Controller (SMC) is shown in Figure 1.…”
Section: Proposed Methodologymentioning
confidence: 99%
“…Shunt active filter is employed to control the inverter pulses. Sliding mode controller is proposed in this paper, which is a non-linear control method to suppress harmonics [16] and reactive power compensation to improve power quality [2]. Shunt active filter with SVC FACTS devices implemented using Sliding Mode Controller (SMC) is shown in Figure 1.…”
Section: Proposed Methodologymentioning
confidence: 99%
“…In this work, I F und is extracted using an ANN-based harmonic extraction algorithm [16,17]. [1,2,19,20].…”
Section: Dc-link Voltage Control Algorithmsmentioning
confidence: 99%
“…The synchronizer algorithm is used to provide a sinusoidal referencing signal to the harmonics extraction algorithm and the DC-Bus voltage regulation algorithm governed by the self-charging technique [37]- [39]. Meanwhile, the split capacitors voltage balancing is achieved via the neutral point voltage control algorithm [40]- [42] which adjusts the incremental time interval according to the detected instantaneous split capacitor voltages ( and ).…”
Section: Proposed Sapf With Control Strategiesmentioning
confidence: 99%
“…The simplification is implemented based on the fact that the zero-sequence current does not exist in balanced three-phase systems [9], [47], [48]. The SAPF is mainly designed to operate in a balanced three-phase system in which the source voltage is assumed to be purely sinusoidal [6], [37], [39]. Thus, the zero-sequence component can be excluded from the calculation.…”
Section: B Proposed Improvements and Simplificationsmentioning
confidence: 99%