2015
DOI: 10.1016/j.promfg.2015.07.047
|View full text |Cite
|
Sign up to set email alerts
|

Improvement of Three-dimensional Motion Analyzer System for the Development of Indonesian Gait Database

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 1 publication
0
6
0
Order By: Relevance
“…Table 2 presents the spatiotemporal parameters of the normal and amputee subjects. The parameters of over ground walking from the study conducted by Chandra et al [8] is used as a comparison. Note that the parameters on the sound and prosthetic foot of amputee are obtained when the markers are attached on the sound and prosthetic foot of amputee subjects, respectively.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Table 2 presents the spatiotemporal parameters of the normal and amputee subjects. The parameters of over ground walking from the study conducted by Chandra et al [8] is used as a comparison. Note that the parameters on the sound and prosthetic foot of amputee are obtained when the markers are attached on the sound and prosthetic foot of amputee subjects, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…The motion analyzer system in the previous study [8] used two cameras that were connected to the frame grabber in the workstation. The cameras used in the system were Sentech STC-CLC33A with the speed 95 frames per second.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The image sequence-based methods generally collect gait information over long distance by camera, and identifies the gait through feature extraction and classification. For instance, Chandra et al [12] successfully recognized gaits with different angles and pedestrian shapes, using the 3D gait data reconstructed by multiple cameras. Kim and Paik [13] combined frieze pattern and dynamic time to match gait sequences with similar angles of view.…”
Section: Literature Reviewmentioning
confidence: 99%
“…The force measuring platform and 3-D motion capture system have been employed in laboratory studies of postural stability [8,9,10]. To maintain an upright stance, the center of mass (COM) should be stable and controllable [11,12,13].…”
Section: Introductionmentioning
confidence: 99%