2012
DOI: 10.1109/tpel.2011.2170709
|View full text |Cite
|
Sign up to set email alerts
|

Improving Output Performance of a Z-Source Sparse Matrix Converter Under Unbalanced Input-Voltage Conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
37
0
1

Year Published

2013
2013
2020
2020

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 64 publications
(38 citation statements)
references
References 30 publications
0
37
0
1
Order By: Relevance
“…Table 2 shows a comparison between the results of this work and the other Z-source matrix converters in different reports in terms of quantity of elements in topology, maximum voltage transfer ratio, the quantity and values of Z-source elements, switching frequency, output current THD and maximum tolerated abnormality of input voltage. The proposed strategy drives an IM under 40% abnormal input voltage, while [27][28][29][30] have launched the static RL load. In the recommended topology, the overall volume and weight of the system is 2.3 L which is considerably lower than the conventional back-to-back converter with a volume of 4.6 L for the same power rating and thermal limitation of the USMC described in [31,32].…”
Section: Discussionmentioning
confidence: 99%
“…Table 2 shows a comparison between the results of this work and the other Z-source matrix converters in different reports in terms of quantity of elements in topology, maximum voltage transfer ratio, the quantity and values of Z-source elements, switching frequency, output current THD and maximum tolerated abnormality of input voltage. The proposed strategy drives an IM under 40% abnormal input voltage, while [27][28][29][30] have launched the static RL load. In the recommended topology, the overall volume and weight of the system is 2.3 L which is considerably lower than the conventional back-to-back converter with a volume of 4.6 L for the same power rating and thermal limitation of the USMC described in [31,32].…”
Section: Discussionmentioning
confidence: 99%
“…Additionally, the active duty cycles (dx and dy) for the modulation of the CSR stage are expressed as in Equation (2). If the reference current phasor is located in sector 1, the average DC-link voltage (VDC(av)) of the fictitious DC link produced by the maximum and second largest magnitudes of the line-to-line voltages generated by the generator is expressed as in Equation (3).…”
Section: Modulation Strategy Of Current Source Rectifier Stagementioning
confidence: 99%
“…Additionally, the active duty cycles (d x and d y ) for the modulation of the CSR stage are expressed as in Equation (2).…”
Section: Modulation Strategy Of Current Source Rectifier Stagementioning
confidence: 99%
See 1 more Smart Citation
“…현재까지 매트릭스 컨버터 분야는 변조 기법, 정류 기 법, 낮은 전압 전달률의 극복, 고조파의 영향 등에 대해 중점적으로 연구되어 왔다 [4][5][6][7][8] . 전력용 반도체로 구성된 스위치 또는 그에 따른 게이트 드라이버 회로는 전력 변환 시스템에서 쉽게 파괴될 수 있으므로 신뢰성의 향 상 문제가 대두되고 있다.…”
unclassified